Behavior of High-Strength Self-Consolidated Reinforced Concrete T-Deep Beams



Hayder H. H. Kamonna1, *, Qasim M. Shakir1, Haider A. Al-Tameemi1
1 Department of Civil Engineering, Faculty of Engineering, University of Kufa, Najaf, Iraq


Article Metrics

CrossRef Citations:
1
Total Statistics:

Full-Text HTML Views: 4793
Abstract HTML Views: 1366
PDF Downloads: 864
ePub Downloads: 695
Total Views/Downloads: 7718
Unique Statistics:

Full-Text HTML Views: 1689
Abstract HTML Views: 611
PDF Downloads: 588
ePub Downloads: 455
Total Views/Downloads: 3343



Creative Commons License
© 2020 Kamonna et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Department of Civil Engineering, Faculty of Engineering, University of Kufa, Najaf, Iraq; Tel: 009647815462886; E-mail: hayder.kammona@uokufa.edu.iq


Abstract

Background:

When a beam is loaded on two opposite faces and the beam’s depth is increased such that either the span-to-depth ratio is smaller than four or the shear-span-to-depth ratio is less than two, it will behave like a deep beam. Strain distribution in deep beams is different from that of ordinary beams because it is nonlinear along with the beam depth. If the beam is cast monolithically with a slab in the slab–beam system, it is considered a T-deep beam. The behavior of the resulting member is more complicated.

Objective:

The effect of flange width on the behavior of high-strength self-consolidated reinforced concrete T-deep beams was investigated.

Methods:

Experimental and numerical studies were conducted. Two shear span-to-depth ratios (1.25 and 0.85) were adopted for two groups. Each group consisted of four specimens: one rectangular beam that served as a reference beam and three flanged beams with flange widths of 440, 660 and 880 mm. All specimens had an overall depth of 450 mm, a width of 160 mm and a total length of 1600 mm. The tests were performed under a two-point load with a clear span of 1400 mm. A nonlinear analysis was also performed using ANSYS software.

Results:

Throughout the study, the performance of the T-deep beams has been investigated in terms of cracking loads, failure loads, modes of failure, loading history, rate of widening of cracks and ductility index. Results revealed that such parameters have a different ranges of effect on the response of T-deep beams. Calibration of the ANSYS model has been done by comparing results of load-deflection curves, cracking and failure loads with that obtained experimentally.

Conclusion:

The study’s results indicated that increasing the flange width yielded an 88% improvement in the failure load and an approximately 68% improvement in the cracking load. This positive effect of flange width on the failure load was more pronounced in beams with higher shear span to- depth ratios and flange widths of 660 mm. In addition, the beam’s ductility was improved, especially in cases corresponding to a higher shear span-to-depth ratio.

The finite element simulation showed good validation in terms of the load-deflection curve with a maximum failure load difference of 9%. In addition, the influence of longitudinal steel reinforcement on the behavior of such members was studied. Some parameters that reflect the effect of changing the flange width on the behavior of deep beams were also presented. Increasing the flange width is more effective when using normal strength concrete than when using high-strength concrete in terms of cracking load, beam stiffness, and failure load.

Keywords: Deep beams, Flanged section, Shear span-to-depth ratio, High strength concrete, Self-consolidated concrete, Nonlinear analysis.