RESEARCH ARTICLE


Performance Based Analysis of a Historic High Rise Building



Anindya Dutta*, 1, Ronald Hamburger, Stephen T. Bono



Article Metrics

CrossRef Citations:
1
Total Statistics:

Full-Text HTML Views: 660
Abstract HTML Views: 1679
PDF Downloads: 835
Total Views/Downloads: 3174
Unique Statistics:

Full-Text HTML Views: 367
Abstract HTML Views: 841
PDF Downloads: 611
Total Views/Downloads: 1819



Creative Commons License
© Dutta et al.; Licensee Bentham Open

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Correspondence: *Address correspondence to this author at the Simpson Gumpertz & Heger, Inc., The Landmark @ One Market Street, Suite 600, San Francisco, CA 95105, USA; Tel: 415-343 3057; Fax: 415-495 3550; E-mail: ADutta@sgh.com


Abstract

The authors employed high-fidelity computer modeling to analyze the probable seismic performance of an existing high-rise, steel frame building with unreinforced masonry infill walls in downtown San Francisco. The Pacific Telephone and Telegraph Co. building at 138 New Montgomery is a 26-story, historic office building. Constructed in 1926 this building was the tallest building in the western United States for a long period of time. The building's structural system comprises perimeter unreinforced brick masonry walls infilled within and supported by a steel frame. We conducted our analysis in support of the building's conversion to residential occupancy. As a result of the occupancy conversion, along with associated architectural modifications throughout the building, Section 3403 of the San Francisco Building Code (SFBC) requires a seismic upgrade such that the building has a code-compliant lateral-force resisting system with no less than 75% of the strength specified by the code for new buildings of similar occupancy and structural system. Since the existing building does not have a lateral force-resisting system recognized by current U.S. codes, compliance with the prescriptive requirements would have required expensive retrofits. Instead, the authors employed a performancebased approach using the existing masonry infilled steel frame for a substantive portion of the building's seismic resistance, together with a new supplemental interior reinforced concrete shear wall. Rather than design to achieve codespecified strength limits, we used nonlinear response history analysis to demonstrate acceptable behavior under Maximum Considered Earthquake (MCE) shaking. Detailed modeling of the interaction between the masonry infill and steel frame is a key component of this approach.

Keywords: Computer modeling, non-linear finite element analysis, performance based analysis.