RESEARCH ARTICLE


Novel Radon Sub-Slab Suctioning System



Torben Valdbjorn Rasmussen*
Danish Building Research Institute, Department of Construction and Health at Aalborg University - Cph, Copenhagen, Denmark.


Article Metrics

CrossRef Citations:
2
Total Statistics:

Full-Text HTML Views: 1335
Abstract HTML Views: 2003
PDF Downloads: 855
Total Views/Downloads: 4193
Unique Statistics:

Full-Text HTML Views: 626
Abstract HTML Views: 1108
PDF Downloads: 564
Total Views/Downloads: 2298



Creative Commons License
© 2013 Torben Valdbjorn Rasmussen;

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Danish Building Research Institute, Department of Construction and Health at Aalborg University - Cph, Copenhagen, Denmark Tel: +45 9940 2272; E-mail: tvr@sbi.aau.dk


Abstract

A new principle for radon protection is currently presented which makes use of a system of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground-floor slab. The function of this system is based on the principles of pressure reduction within the zone below the ground-floor construction. For this purpose a new system of prefabricated lightweight elements is introduced. The effectiveness of the system is demonstrated for the case of a ground-floor reinforced concrete slab situated on top of a rigid insulation layer (consisting of a thermal insulation layer located on top of a capillary-breaking layer) mounted in turn on stable ground. The new system of prefabricated lightweight elements consists of the capillary-breaking layer and a pressure-reduction zone which is working as the radonsuction zone. The radon-suctioning layer is formed from a grid of horizontal air ducts with low pressure which are able to remove air and radon from the ground. Results showed the system to be effective in preventing radon infiltrating from the ground through the ground-floor slab, avoiding high concentrations of radon being accumulated inside houses. For the system to be effective, the pressure within the ducts must be lower than the pressure inside the house. The new principle was shown to be effective in preventing radon from polluting the indoor air by introducing low pressure in the horizontal grid of air ducts. A lower pressure than the pressure inside the building must be established. The prefabricated lightweight elements were integrated into the insulation layer below the material of the ground-floor slab. The element and the insulation material were made of expanded polystyrene. The new element can be handled by one man on site.

Keywords: Radon, protection, sub-slab.