RESEARCH ARTICLE


Development of Ductile Truss System Using Double Small Buckling-Restrained Braces: Analytical Study



Hidajat Sugihardjo*, Yudha Lesmana, Dwi Prasetya
Department of Civil Engineering, Institut Teknologi Sepuluh Nopember (ITS), Surabaya, Indonesia


Article Metrics

CrossRef Citations:
1
Total Statistics:

Full-Text HTML Views: 1481
Abstract HTML Views: 558
PDF Downloads: 326
ePub Downloads: 295
Total Views/Downloads: 2660
Unique Statistics:

Full-Text HTML Views: 815
Abstract HTML Views: 348
PDF Downloads: 248
ePub Downloads: 224
Total Views/Downloads: 1635



Creative Commons License
© 2019 Sugihardjo et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at the Department of Civil Engineering, Institut Teknologi Sepuluh Nopember (ITS), Surabaya, Indonesia; Tel: 62315946096; E-mails: hidajat.sugihardjo@gmail.com and hidayat@ce.its.ac.id.


Abstract

Introdution:

This paper proposed a Small Buckling-Restrained Brace (SBRB) for the ductile truss moment frames and is called here as the Double Braced Truss Moment Frames (DB-TMF). The braces are located at the edge of the truss girder and are only placed around the building perimeter. The braces work in pair as a weak element (structural fuses) and is expected to effectively absorb the seismic energy. The proposed DB-TMF system is an extended development of the Knee Braced Truss Moment Frames (KB-TMF). The DB-TMF system is expected to carry the whole seismic loads, while the rest of the frame is designed to carry only the gravity loads.

Methods:

To study the performance of the proposed DB-TMF system, non-linear finite element analysis was carried out using the DRAIN-2DX package. From the analysis with various time history records, it was found that the drift ratio of the DB-TMF system is lower than the allowed story drift. The roof-top displacement shows an asymptotic behavior. The shape of the hysteresis curve tends to have a pinching shape. However, the cumulative ductility of the proposed system satisfies the requirements as a hysteretic structure. In the event of an earthquake, only the SBRB and the chords adjacent to the column element are damaged while the rest of the structural elements remain elastic which is expected.

Results and Conclusion:

Based on the performance evaluation of the DB-TMF system, the DB-TMF system is suitable for moderate seismic region and has smaller dimension steel sections compared to the KB-TMF system.

Keywords: Double small buckling-retrained braces, Cumulative ductility, Hysteretic structure, Ductile truss moment frames, KB-TMF, STMF, Low yield strength.