RESEARCH ARTICLE


Implantable Cardioverter Defibrillator Therapy: A Single Center Experience in Saudi Arabia



Ahmad S Hersi*
Department of Cardiac Sciences, College of Medicine, King Saud University, Riyadh KSA


Article Metrics

CrossRef Citations:
1
Total Statistics:

Full-Text HTML Views: 1315
Abstract HTML Views: 569
PDF Downloads: 348
Total Views/Downloads: 2232
Unique Statistics:

Full-Text HTML Views: 565
Abstract HTML Views: 360
PDF Downloads: 262
Total Views/Downloads: 1187



Creative Commons License
© Ahmad S. Hersi; Licensee Bentham Open.

open-access license: This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.

* Address correspondence to this author at the Department of Cardiac Sciences, College of Medicine, King Saud University, Riyadh KSA, Tel: +96614671161; Fax: +9664671158; E-mail: ahersi@ksu.edu.sa


Abstract

Introduction:

Internal Cardioverter Defibrillators (ICD) has been shown to decrease mortality in patients such as those with structural heart disease or at high risk of sudden cardiac death. To date there is no data regarding the clinical features, and outcomes of ICD patients in Saudi Arabia. Accordingly, we explored the clinical features and outcomes of ICD therapy among Saudis.

Methods:

Patients who had ICD implantation in King Khalid University Hospital from November 2007 until January 2010 were enrolled.

Results:

One hundred and eight ICD were implanted between November 2007 and February 2010. The mean age was 58.6±13.2 years. The majority were male 94 (87%), the rate of Diabetes Mellitus (DM) was 58.3%, Hypertension (HTN) was 61.1%, and 63% were smokers. The mean ejection fraction (EF) was 24.5%. Of the 108 patient 90(83.3%) had ICD insertion for primary prevention and 18(16.7%) for secondary prevention. Of the 90 patients who ICD for primary prevention 62 (57.4%) had ischemic cardiomyopathy, 39(36.1%) had dilated cardiomyopathy and 7 (6.5%) had channelopathy. Over a mean follow-up of 18 months 4 (3.7%) died.

Conclusions:

Our study describes for the first time patients characteristic and outcomes for ICD therapy in Saudi Arabia. Our patients are younger and have higher prevalence of risk factors that those in Western countries.

Keywords: Implantable Cardioverter-Defibrillator, Saudi Arabia..