The Open Dentistry Journal




ISSN: 1874-2106 ― Volume 14, 2020
RESEARCH ARTICLE

Curing Depth and Degree of Conversion of Five Bulk-Fill Composite Resins Compared to a Conventional Composite



Samaneh Rezaei1, 2, Mehdi Abbasi2, Farzaneh Sadeghi Mahounak2, Zohreh Moradi2, *
1 Department of Restorative Dentistry, School of Dentistry, Arak University of Medical Science, Arak, Iran
2 Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Science, Tehran, Iran

Abstract

Background:

Limited curing depth and its effect on the degree of conversion are among the challenges of working with light-cure composite resins. The use of bulk-fill composites is one strategy to overcome these limitations.

Methods:

Ever X Posterior (EXP), Filtek Bulk-Fill Posterior (FBP), Sonic Fill 2 (SF2), Tetric N-Ceram Bulk-Fill (TNB), and X-tra Fil (XF) bulk-fill and Filtek Z250 conventional composite were evaluated in this in vitro experimental study. Six samples for the assessment of microhardness and three samples for the evaluation of DC were fabricated of each composite. After light curing and polishing, the samples were incubated at 37°C for 24 hours. Microhardness was measured by a Vickers hardness tester three times and the mean value was calculated. DC of the top and bottom surfaces was determined using Fourier-Transform Infrared Spectroscopy (FTIR). Data were analyzed using one-way ANOVA and Tukey’s test.

Results:

Microhardness and DC were significantly different among the groups (P<0.001). XF and Z250 equally showed the highest bottom-to-top surface microhardness ratio (0.97 ± 0.01) and significantly higher DC in the top (P<0.001) and bottom (P<0.005) surfaces compared to other groups. TNB showed the lowest microhardness ratio (0.88 ± 0.04) and DC (68.66 ± 1.52 and 61.00 ± 2.00); the difference in DC of the bottom surface was statistically significant (P<0.003).

Conclusion:

It appears that bulk-fill composites evaluated in this study are adequately polymerized at 4 mm depth. Their DC was optimal and within the range of conventional composites.

Keywords: Ever X Posterior (EXP), Composite resins, Hardness tests, Fourier transform infrared spectroscopy, Filtek Z250, X-tra fil composite resin.


Article Information


Identifiers and Pagination:

Year: 2019
Volume: 13
First Page: 422
Last Page: 429
Publisher Id: TODENTJ-13-422
DOI: 10.2174/1874210601913010422

Article History:

Received Date: 13/07/2019
Revision Received Date: 19/10/2019
Acceptance Date: 21/11/2019
Electronic publication date: 31/12/2019
Collection year: 2019

© 2019 Rezaee et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.


* Address correspondence to this author at the Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Science, North Kargar St, Po. Code: 14399-55991, Tehran, Iran; Tel: +98-912-1242140; Fax: +9821-88015950; E-mail: zohrehmoradi2003@yahoo.com



Track Your Manuscript:


Endorsements



"Thank you for your magnificent and marvelous support throughout the publication stages. I would like to endorse my experience with you as a Junior Researcher and a recent graduate of the Dental school. Once again Thank you for your Great Help and Guidance throughout the stages of Publication. You guys are a great team and I am proud to be a Young Bentham author."


Asra Sabir Hussain
The University of Edinburgh Business School, UK

"My experience with Bentham Open was a valuable one because the quality of the services and analysis of my paper contributed in improving what we intended to convey to the readers."


José Ricardo Kina
Department of Surgery and Integrated Clinic,
Araçatuba School of Dentistry, São Paulo State University
Brazil

"The Publication Manager was very cooperative and replied my mails and guided me without any delays; however the reviewing process was too long."


Mahtab Memarpour
Prevention of Oral and Dental Disease Research Center,
Department of Pediatric Dentistry, School of Dentistry,
Shiraz University of Medical Sciences, Shiraz,
Iran


Browse Contents



Webmaster Contact: info@benthamopen.net
Copyright © 2020 Bentham Open