CASE REPORT


Modified Open Suprapectoral EndoButton Tension Slide Tenodesis Technique of Long Head of Biceps with Restored Tendon Tension–Length



Jagadish Prabhu, Mohammed Khalid Faqi*, Rashad Khamis Awad, Fahad Alkhalifa
Bahrain Defence Force Hospital - Royal Medical Services, Riffa, Kingdom of Bahrain


Article Metrics

CrossRef Citations:
3
Total Statistics:

Full-Text HTML Views: 1784
Abstract HTML Views: 454
PDF Downloads: 367
ePub Downloads: 282
Total Views/Downloads: 2887
Unique Statistics:

Full-Text HTML Views: 943
Abstract HTML Views: 296
PDF Downloads: 251
ePub Downloads: 215
Total Views/Downloads: 1705



Creative Commons License
© 2017 Prabhu et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

* Address correspondence to this author at Department of Orthopaedics, BDF Hospital and Royal Medical Services, Riffa, Kingdom of Bahrain; Tel: +973-39150431; E-mail: drmfaqi@gmail.com


Abstract

Background:

The vast majority of biceps tendon ruptures occurs at the proximal insertion and almost always involves the long head. There are several options for long head of biceps (LHB) tenodesis with advantage and disadvantages of each technique. We believe that the suprapectoral LHB tenodesis described in this article enables the restoration of the anatomic length-tension relation in a technically reproducible manner, when following the guidelines set forth in this article, and restores biceps contour and function adequately with a low risk of complications.

Method:

We present a case of a young man who had a sudden jerk of his flexed right elbow, while involved in water skiing sports and sustained complete rupture of proximal end of long head of biceps tendon. In this article, we describe a modified surgical technique of open supra-pectoral long head of biceps tenodesis using an EndoButton tension slide technique, reproducing an anatomic length-tension relationship.

Results:

By the end of one year, patient regained symmetrical muscle bulk, shape and contour of biceps compared to other side. There were no signs of dislodgement or loosening of the EndoButton on follow-up radiographs. He regained full muscle power in the biceps without any possible complications, such as humeral fracture, infection, or nerve injury, associated with this technique.

Conclusion:

This technique is a safe, easy to reproduce, cost-effective, less time consuming and an effective method that uses a small drill hole, conserving bone, minimizing trauma to the tendon, and decreasing postoperative complications. It does not need any special instrumentation and is suitable especially for use in centers where arthroscopy facility or training is not available.

Keywords: Biceps rupture, Eendobutton, Ttendon sliding techniques/instrumentation, Ttenodesis.