Table 1: Strength (F) and stiffness (K) properties of the equivalent diagonal compression strut (For notation refer to Fig. (2b)).

fm
[MPa]
Width
[m]
Height
[m]
Stiffness K1
[kN/m]
Fy = F1
[kN]
Fmax = F2
[kN]
u2
[m]
K3 / K1 u3
[m]
F3 = F4
[kN]
2.5 3.5 2.5 27859.5 121.5 243.0 0.015 -0.10 0.089 36.5