Table 11: Montbau buildings without rehabilitating year 25 and 50. Total consumption of heating energy, CO2 eq and economic scenario cost of 6% (Data from the study and consulted on http://hdl.handle.net/ buildings 10803/285002).

Year 25 Type of building Constructed area Total heating energy kWh Heating energykWh/m2 Total emissions Kg CO2 eq Emissions Kg CO2 eq/m2 Heating energy cost 6% € Heating energy cost 6% €/m2
BUILDING A Duplex 3.954 5.010.460 1.267,19 1.378.858 348,72 782.248 197,84
BUILDING E - F Lineal 2.599 2.857.920 1.099,62 787.280 302,92 448.819 172,69
BUILDING Q Tower 3.524 3.753.880 1.065,23 1.033.552 293,29 587.719 166,78
SINGLE FAMILY 14 single family 1.353 1.768.910 1.307,40 485.290 358,68 271.232 200,47
Year 50 Type of building Constructed area Total heating energy kWh Heating energykWh/m2 Total emissions Kg CO2 eq Emissions Kg CO2 eq/m2 Heating energy cost 6% € Heating energy cost 6% €/m2
BUILDING A Duplex 3.954 9.828.210 2.485,64 2.704.683 684,04 4.082.990 1.032,62
BUILDING E - F Lineal 2.599 5.605.920 2.156,95 1.544.280 594,18 2.342.532 901,32
BUILDING Q Tower 3.524 7.363.380 2.089,49 2.027.352 575,30 3.067.491 870,46
SINGLE FAMILY 14 single family 1.353 3.469.785 2.564,51 951.915 703,56 1.415.647 1.046,30