Batch Quantities (g) for Twelve 50-mm3 Mortar Specimens | ||||||||
---|---|---|---|---|---|---|---|---|
Mix ID |
Cement Replacement (%) |
Water (w) | Cement (c) | GF | GSF | SF | SSF | Sand (s) |
Control Mortar (CM) | 0 | 485 | 1000 | 0 | 0 | 0 | 0 | 2750 |
5% GF (GF5) | 5 | 950 | 50 | 0 | 0 | 0 | ||
10% GF (GF10) | 10 | 900 | 100 | 0 | 0 | 0 | ||
15% GF (GF15) | 15 | 850 | 150 | 0 | 0 | 0 | ||
20% GF (GF20) | 20 | 800 | 200 | 0 | 0 | 0 | ||
5% GSF (GSF5) | 5 | 950 | 0 | 50 | 0 | 0 | ||
10% GSF (GSF10) | 10 | 900 | 0 | 100 | 0 | 0 | ||
15% GSF (GSF15) | 15 | 850 | 0 | 150 | 0 | 0 | ||
20% GSF (GSF20) | 20 | 800 | 0 | 200 | 0 | 0 | ||
10% SF (SF10) | 10 | 900 | 0 | 0 | 100 | 0 | ||
20% SF (SF20) | 20 | 800 | 0 | 0 | 200 | 0 | ||
30% SF (SF30) | 30 | 700 | 0 | 0 | 300 | 0 | ||
10% SSF (SSF10) | 10 | 900 | 0 | 0 | 0 | 100 | ||
20% SSF (SSF20) | 20 | 800 | 0 | 0 | 0 | 200 | ||
30% SSF (SSF30) | 30 | 700 | 0 | 0 | 0 | 300 |