Table 4: Comparison of analytical and numerical values of Tangential Force per Unit Length in Wall and hopper.

Case no. Depth
(m)
F(Tangential
Force, Analytical)
F(Tangential
Force, Numerical)
%
Difference
F(Longitudinal
Force, Analytical)
F(Longitudinal
Force, Numerical)
%
Difference
Case-1 6.114 213.12 131 38
10.33 341.76 337 1.2
23 619.7 534 13
24.125 878.75 1183.25 25 727 1193 39
25.17 304.8 411.12 26 497 527 5.6
26.17 17.73 20.52 15 57 170 66
Case-1 2.92 66.2 40.7 39
7.46 156.1 153.9 2
12 811 698.8 13
12.9 188 155.84 17 259.9 262.04 0.7
13.3 70 114.14 38 94.35 120.94 22
13.7 6.98 22.4 68 8 66.3 87
Case-3 4 217.94 134 61
9.5 481.90 475.2 1.2
15 668.52 576.1 13
15.775 501.88 415.25 17 562.18 566.75 0.7
16.525 136.1 222 38 159.1 264.5 39
17.275 10.4 33.45 69 11.45 94.85 88
Case-4 6.995 170 104.5 38
17.5 385 380 1.2
28 529.1 456 13
29.2 815.75 675 17 864.36 871.5 0.8
30.75 202.2 330 38 318.2 408 22
31.75 13.8 44.4 68 14.9 123.4 88