Table 2: Validation studies from literature.

Comparable Validation Parameters Present Study Available Literature
For 25% of femur length from femoral head
(load applied 3000N)
displacement in Z axis
0.42mm 0.4mm [4]
For 50% of femur length and fixed the bottom surface
(the load applied 3000N)
Total displacement
5.7mm 4.2mm [7]
For 75% of femur length from femoral head
(load applied 1000N)
Total displacement
3.5mm 3.3mm [11]
For 25% of femur length from femoral head
(load applied 1000N)
von Mises Stress
17.5MPa 17.49MPa [9]
19MPa [10]
For 75% of full length femur
(load applied of 3000N)
von Mises Stress
63.017MPa 57.17MPa [19]