Comparable Validation Parameters | Present Study | Available Literature |
---|---|---|
For 25% of femur length from femoral head (load applied 3000N) displacement in Z axis |
0.42mm | 0.4mm [4] |
For 50% of femur length and fixed the bottom surface (the load applied 3000N) Total displacement |
5.7mm | 4.2mm [7] |
For 75% of femur length from femoral head (load applied 1000N) Total displacement |
3.5mm | 3.3mm [11] |
For 25% of femur length from femoral head (load applied 1000N) von Mises Stress |
17.5MPa | 17.49MPa [9] 19MPa [10] |
For 75% of full length femur (load applied of 3000N) von Mises Stress |
63.017MPa | 57.17MPa [19] |