Table 2: Static load test.

Stirring cored pile number Estimated ultimate bearing capacity design / kN Test pile
Length
/ m
Maximum loading
/ kN
Maximum Settlement
/mm
Vertical Ultimate Bearing Capacity / kN Corresponding settlement
/ mm
Corresponding
Loading
/ kN
3# 950 10.0 900 16.29 ≥900 16.29 850
5# 950 10.0 810 46.15 540 10.67 743
6# 950 10.0 630 55.91 540 12.88 600
7# 950 10.0 630 69.05 540 17.94 600
8# 950 10.0 900 53.95 540 16.36 850
9# 950 10.0 720 60.40 540 12.31 690