Table 9: Floor displacements of the 7-story frame structure when the amount of explosion charge is 400 kg.

Floors 200 m 300 m 400 m
Floor displacement
(m)
Story drift
(m)
Floor displacement
(m)
Story drift
(m)
Floor displacement
(m)
Story drift
(m)
1   1.747E-02 1.747E-02 1.032E-02 1.032E-02 9.318E-03 9.318E-03
2 3.345E-02 1.598E-02 1.883E-02 8.510E-03 1.700E-02 7.682E-03
3 5.077E-02 1.732E-02 2.541E-02 6.580E-03 2.294E-02 5.940E-03
4 6.259E-02 1.182E-02 3.078E-02 5.370E-03 2.779E-02 4.850E-03
5 7.113E-02 8.540E-03 3.891E-02 8.130E-03 3.513E-02 7.340E-03
6 8.330E-02 1.217E-02 4.406E-02 5.150E-03 3.978E-02 4.650E-03
7 9.224E-02 8.940E-03 4.607E-02 2.010E-03 4.159E-02 1.810E-03