Table 3: Comparison between GAI Prototype Test Results [9] and Predicted Capacities.

Test Designation Measured Mu (kN-m) Predicted Mu (kN-m) Ratio of Predicted/Measured
(1) (2) (3) (4)
Test 7 916 1014 1.107
Test 8 300 512 1.707
Test 9 231 293 1.268