equivalent viscous damping | ΞΎCBF | [%] | 8.6 |
SMA brace secant stiffness-story 3 | KSMAsec,3 | [N/mm] | 9.0298e+003 |
SMA brace secant stiffness-story 3/diagonal elastic stiffness-story 3 | KSMAsec,3/KDIAGel,3 | - | 0.2068 |
SMA brace cross section area - story 3 | ASMA3 | [mm2] | 290.91 |
SMA brace length - story 3 | LSMA3 | [mm] | 311.43 |