Table 7: Parameters characterizing the CBF-5s-SMA-s1 solution.

equivalent viscous damping ΞΎCBF [%] 8.43
SMA brace secant stiffness-story 1 KSMAsec,1 [N/mm] 8.7378e+004
SMA brace secant stiffness-story 1/diagonal elastic stiffness-story 1 KSMAsec,1/KDIAGel,1 - 0.4671
SMA brace cross section area - story 1 ASMA1 [mm2] 1.4246e+003
SMA brace length - story 1 LSMA1 [mm] 157.6104