Table 8: Parameters characterizing the CBF-5s-SMA-s1,2 solution.

equivalent viscous damping ΞΎCBF [%] 8.44
SMA brace secant stiffness-story 1 KSMAsec,1 [N/mm] 2.5858e+005
SMA brace secant stiffness-story 2 KSMAsec,2 [N/mm] 2.3848e+005
SMA brace secant stiffness-story 1/diagonal elastic stiffness-story 1 KSMAsec,1/KDIAGel,1 - 1.3823
SMA brace secant stiffness-story 2/diagonal elastic stiffness-story 2 KSMAsec,2/KDIAGel,2 - 1.2748
SMA brace cross section area - story 1 ASMA1 [mm2] 1.4243e+003
SMA brace cross section area - story 2 ASMA2 [mm2] 1.3136e+003
SMA brace length - story 1 LSMA1 [mm] 53.2469
SMA brace length - story 2 LSMA2 [mm] 53.2469