Table 7: Comparison between Ultimate Loads Obtained Using Experimental Results and Different Analytical Methods.

Beam Designation PExp.
(kN)
PAn.
STM ACI
318R-14Code
(kN)
Modified STM
by Zhang and
Tan
(kN)
*Modified STM
by Zhang and
Tan
(kN)
B-HS-M-Hy 1- ρw 0 570 567 778 797
B-HS-M-Hy 2- ρw 0 670 582 877 901
B-HS-M-HSC 0- ρw 0 520 527 748 763
X'(PAn/PExp.) 1.25 1.17 1.32
SD 0.07 0.26 0.27
CV 0.073 0.22 0.2

* Size Effect on the Capacity of Deep Beams Using the STM.