Table 10: Comparison between experimental ultimate loads and those calculated using STM of ACI 318R-14Code [1].

Beam Designation ρw Type of Beam SF
(%)
Ultimate Load(2Vn)
(kN)
% PAn/PExp.
STM ACI 318R-14 Code Experimental Value
B-HS-M-FHSC 1- ρw 4 0.004
(Min.)
Non-Hybrid
(FHSC)
1 694 810 0.86
B-HS-M-Hy 1- ρw 4 0.004 Hybrid 1 694 730 0.95
B- HS-M-Hy1- ρw 6 0.006
(>Min.)
Hybrid 1 694 900 0.77
B-NS-M-Hy1- ρw 4 0.004 Hybrid 1 360 370 0.97
B-HS-M-HSC 0- ρw 4 0.004 Non-Hybrid
(HSC)
0 699 610 1.14

X' =0.94 SD. = 0.14 CV. = 0.15