Table 13:
Grading of recycled fine aggregate.
Size of Sieve, mm
% Passing
Limits of Iraqi Standard IQS 45-1984, Zone 2
10
100
100
4.75
99.65
90-100
2.36
92.32
75-100
1.18
64.15
55-90
0.6
45.19
35-59
0.3
26.78
8-30
0.15
3.11
0-10
*Grading tests were made in the material laboratory, College of Engineering, Al-Mustansiriyah University.