The Open Civil Engineering Journal




ISSN: 1874-1495 ― Volume 13, 2019
RESEARCH ARTICLE

Seismic Fragility of Tall Concrete Wall Structures in Malaysia under Far-Field Earthquakes



Siti Aisyah1, Mohammadreza Vafaei1, *, Sophia C. Alih2, Kotaiba Aljwim1
1 Faculty of Engineering, School of Civil Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia
2 Inistitute of Noise and Vibration, School of Civil Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia

Abstract

Introduction:

In recent years, the seismic vulnerability of structures in Malaysia has attracted the attention of researchers mainly because the majority of existing structures have not been designed for seismic actions. In this study, seismic vulnerability of tall concrete wall buildings has been investigated through the development of seismic fragility curves.

Methods:

Two 25-story tall buildings with similar plans but with the different number of parking levels were analyzed through the incremental dynamic analysis. The tall buildings were excited by 15 far-field earthquakes, and their inter-story drift demands and capacities were estimated. Nonlinear response of beams and columns was simulated through the lumped plasticity model. The inelastic response of concrete walls was taken into account through the use of distributed plasticity fibre-based elements.

Results and Conclusion:

The obtained results indicated that the probability of exceeding minor damage to the tall concrete wall buildings located in the Kuala Lumpur city was around 55%. However, the probability of collapse of these structures in the same city was less than 15%.

Keywords: Seismic Fragility, Tall buildings, Incremental dynamic analysis, Malaysia, Far-field earthquakes, Concrete wall structures.


Article Information


Identifiers and Pagination:

Year: 2019
Volume: 13
First Page: 140
Last Page: 146
Publisher Id: TOCIEJ-13-140
DOI: 10.2174/1874149501913010140

Article History:

Received Date: 20/07/2019
Revision Received Date: 12/08/2019
Acceptance Date: 29/08/2019
Electronic publication date: 15/11/2019

Article Metrics:

CrossRef Citations:
0

Total Statistics:

Full-Text HTML Views: 236
Abstract HTML Views: 108
PDF Downloads: 67
ePub Downloads: 44
Total Views/Downloads: 455

Unique Statistics:

Full-Text HTML Views: 141
Abstract HTML Views: 64
PDF Downloads: 57
ePub Downloads: 36
Total Views/Downloads: 298
Geographical View

© 2019 Aisyah et al.

open-access license: This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.


* Address correspondence to this author at Faculty of Engineering, School of Civil Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia
Tel: +607-5531684 | Ext.:31684; Fax: +607-5566157; E-mail: vafaei@utm.my






1. INTRODUCTION

In line with the urbanization and development of the country, the number of tall buildings in Malaysia has been increased rapidly. Tall buildings that have been constructed in major cities in Malaysia ranged from 20 to 50 stories and are used for office or residential purposes. In Malaysia, Reinforced Concrete (RC) is the common material that is used for the construction of tall buildings because of the country’s environmental condition and cost-effectiveness of RC materials. Moreover, concrete walls are the main lateral force resisting system for the majority of tall buildings in Malaysia. As it is shown in Fig. (1), at the lower level of tall buildings, a few stories are used as the parking area. These stories are made by moment-resisting frames so that enough open area is provided for cars to maneuver and park. Above the parking levels, concrete walls are constructed on wide transfer beams. In other words, the majority of concrete walls used in the tall buildings do not continue to the foundation of the structures. Therefore, because of the relatively lower stiffness of parking levels compared to the concrete walls of upper levels, these tall buildings can exhibit a complex dynamic response during a seismic event.

Although some weak earthquakes have been reported within the territory of the country, Malaysia has been shaken mostly by the world’s most active faults that lay in Indonesia and Philippine. During the past decades, Peninsular Malaysia has been hit mostly by the distant-earthquakes from Sumatra subduction zone, while Eastern Malaysia has been subjected to large earthquakes from the Southern Philippines [1S.C. Alih, and M. Vafaei, "Performance of reinforced concrete buildings and wooden structures during the 2015 Mw 6.0 Sabah earthquake in Malaysia", Eng. Fail. Anal., vol. 102, pp. 351-368.
[http://dx.doi.org/10.1016/j.engfailanal.2019.04.056]
]. Light damage to some buildings in Malaysia has also been reported due to the far-field earthquakes, for example the Sumatra earthquakes during 2002 and 2004. Because of its low seismicity, Malaysia received its first national annex for the seismic design of structures in the early 2017. Therefore, many of the existing structures, including tall buildings, have not been designed for seismic actions. The seismic vulnerability of existing tall buildings needs to be evaluated because seismic-induced damage to the tall buildings will give a massive impact on Malaysia’s financial condition and can endanger human life.

Fig. (1)
A common type of tall building in Malaysia.


Researchers have widely used fragility curves to investigate the vulnerability of different types of structures when subjected to seismic actions [2F. Cui, H. Zhang, M. Ghosn, and Y. Xu, "Seismic fragility analysis of deteriorating RC bridge substructures subject to marine chloride-induced corrosion", Eng. Struct., vol. 155, pp. 61-72.
[http://dx.doi.org/10.1016/j.engstruct.2017.10.067]
-4L. Su, "Seismic fragility analysis of pile-supported wharves with the influence of soil permeability", Soil. Dyn. Earthquake Eng., vol. 122, pp. 211-227.
[http://dx.doi.org/10.1016/j.soildyn.2019.04.003]
]. Fragility curves are defined as the probability of reaching or exceeding a specific damage level under the earthquake excitation [5H. Sadraddin, S. Xiaoyun, and H. Yufeng, "Fragility assessment of high-rise reinforced concrete buildings considering the effects of shear wall contributions", The Struct. Des. Tall Spec. Build., vol. 24, p. 421-439.]. In general, there are two main methods to develop fragility curves that include empirical [6D. Gautam, G. Fabbrocino, and F. Santucci de Magistris, "Derive empirical fragility functions for Nepali residential buildings", Eng. Struct., vol. 171, pp. 617-628.
[http://dx.doi.org/10.1016/j.engstruct.2018.06.018]
] or analytical approaches [7M. Vafaei, and S.C. Alih, "Seismic vulnerability of air traffic control towers", Nat. Hazards, vol. 90, no. 2, pp. 803-822.
[http://dx.doi.org/10.1007/s11069-017-3072-3]
]. The empirical method is based on the typological, field survey and expert judgment. This method consumes a lot of time and is costly; however, it shows a realistic picture of seismic vulnerability as it considers all the influential factors, including the site characteristics. The analytical method, on the other hand, uses simulated data in order to extract the seismic fragility curves of structures. Data produced based on the analytical method is less biased because many types of uncertainties can be considered in the analysis. The analytical approach has gained a lot of attention during the past decades and now is a popular method for derivation of fragility curves. For examples, Mwafy [8A. Mwafy, "Analytically derived fragility relationships for the modern high-rise buildings in the UAE", Struct. Des. Tall Spec. Build., vol. 21, no. 11, pp. 824-843.
[http://dx.doi.org/10.1002/tal.642]
] used an analytical approach to derived seismic fragility curves of modern high-rise buildings in the UAE. In another study, Yang et al. [9C-S.W. Yang, S.D. Werner, and R. DesRoches, "Seismic fragility analysis of skewed bridges in the central southeastern United States", Eng. Struct., vol. 83, pp. 116-128.
[http://dx.doi.org/10.1016/j.engstruct.2014.10.025]
] derived seismic fragility of skewed bridges in the central and southeastern United States. Seismic vulnerability of elevated steel storage tanks supported by reinforced concrete columns was also investigated through an analytical approach by Phan et al. [10H.N. Phan, F. Paolacci, O.S. Bursi, and N. Tondini, "Seismic fragility analysis of elevated steel storage tanks supported by reinforced concrete columns", J. Loss Prev. Process Ind., vol. 47, pp. 57-65.
[http://dx.doi.org/10.1016/j.jlp.2017.02.017]
].

Previous research on the seismic vulnerability of structures in Malaysia has been limited to concrete box girder bridges [11A. Ghazali, H. Al-Haris Alaydrus, S.C. Alih, and M. Vafaei, "Seismic fragility of concrete box girder bridges in Malaysia", IOP Conf. Ser. Mater. Sci. Eng., vol. vol. 513, p. 012019.
[http://dx.doi.org/10.1088/1757-899X/513/1/012019]
], low and mid-rise RC buildings [12K.T. Tan, M. Suhatril, H.A. Razak, and D. Lu, "Seismic vulnerability of low- and mid-rise reinforced concrete buildings in malaysia designed by considering only gravity loads", Arab. J. Sci. Eng., vol. 43, no. 4, pp. 1641-1654.
[http://dx.doi.org/10.1007/s13369-017-2675-z]
-16M. Vafaei, S. C. Alih, and Q. Abdul Rahman, "Drift demands of low-ductile moment resistance frames (MRF) under far field earthquake excitations", J. Teknol., vol. 78, no. 6, .
[http://dx.doi.org/10.11113/jt.v78.5076]
], and industrial structures [17R. Ahmadi, F.M. Nazri, K. Pilakoutas, R. Mulyani, and I. Hajirasouliha, "Seismic vulnerability assessment of an industrial building in peninsular Malaysia", 5th Brunei Int. Conf. Eng. Technol. (BICET 2014), pp. 307-313.
[http://dx.doi.org/10.1049/cp.2014.1124]
]. Hence, in this study, the seismic vulnerability of tall concrete wall buildings in Malaysia has been investigated through the derivation of fragility curves.

2. METHODS

2.1. Selected Buildings

In this study, the seismic vulnerability of two tall buildings was investigated. Both buildings have 25 stories, however, as it is shown in Fig. (2), the first building has five levels for parking area while the second building has three levels for the parking area. As it is shown in Fig. (3), both buildings share a similar plan for the parking levels and residential stories. Besides, in both buildings, a concrete slab with a thickness of 0.17 m covers all the floors. The buildings were designed only for the gravity and wind loads following the standard practice in Malaysia. The live load for residential stories was 2 kN/m2, and for parking levels, it was 5 kN/m2. Moreover, a superimposed load of 1.6 kN/m2 and 1.2 kN/m2 were applied to the residential and parking stories, respectively. The wind load was calculated for a basic wind speed of 33 m/sec and the exposure category B in accordance with the specifications of ASCE 7-10 [18ASCE/SEI 7-10, Minimum design loads for buildings and other structures, american society of civil engineers, reston, virginia, 2010, ]. The design of structural elements, including beams, columns, and walls, was based on specifications of BS8110 [19B. Standard, BS8110-1, "Structural use of concrete, code of practice for design and construction" part 1, 1997, ] as it is practiced in Malaysia. In the design of structural elements, the compressive strength of concrete was assumed 40 MPa, and the yield strength of reinforcing bars was considered 460 MPa. From the design of structural elements it was obtained that at the upper parking levels, where the concrete walls start, the size of beams was 0.75 m by 0.70 m. On the other floors of parking levels, the size of beams was 0.55 m by 0.50 m. The dimensions of columns in the parking levels varied from 0.70 m by 0.70 m at lower levels to 0.45 m by 0.45 m at upper levels. The concrete walls’ thickness also ranged from 0.15 m at lower levels to 0.10 m at top levels. A reinforcement ratio of 1.2% to 4.4% was obtained for columns. For concrete walls, the longitudinal reinforcement ratios varied from 0.56% at lower levels to 0.25% at upper levels. A minimum transverse reinforcement ratio of 0.25% was sufficient for all concrete shear walls.

2.2. Finite Element Simulation

Since the nonlinear analysis of 3-dimensioanl tall buildings is computationally time- consuming, a two-dimensional idealization is often adopted to develop the fragility relationships [8A. Mwafy, "Analytically derived fragility relationships for the modern high-rise buildings in the UAE", Struct. Des. Tall Spec. Build., vol. 21, no. 11, pp. 824-843.
[http://dx.doi.org/10.1002/tal.642]
]. Therefore, in this study, the framing systems located on axis A and B were selected for derivation of fragility curves. The finite element models of the idealized framing systems are shown in Fig. (4). As can be seen from the figure, the idealized systems include the beam and columns of parking levels together with concrete slabs and shear walls. It should be mentioned that the vertical stiffness of concrete slabs in the idealized models was calculated on the basis of the elastic stiffness in the 3-dimensioanl models. Finite element models were established in CSI ETABS software program [20CSI, ETABS. ‘V-16’: Integrated finite element analysis and design of structures basic analysis reference manual, Computers and StructuresInc, 2016, ]. Nonlinear behavior of beams and columns were simulated through the lumped plastic hinge model [21M. Vafaei, S. C. Alih, and A. Fallah, "The accuracy of the lumped plasticity model for estimating nonlinear behavior of reinforced concrete frames under gradually increasing vertical loads", Struct. Concr, .
[http://dx.doi.org/10.1002/suco.201800357]
]. Plastic hinges were assigned to both ends of beams and columns. As it is shown in Fig. (5a) the moment-rotation relationships of plastic hinges together with their limit states were established on the basis of the specifications of ASCE 41 [22ASCE/SEI 41-13: Seismic evaluation and retrofit of existin buildings, american society of civil engineers, reston, virginia, 2014., ]. Nonlinear behavior of concrete walls was simulated using the distributed plasticity fiber based elements [23Y. Lu, and R.S. Henry, "Numerical modelling of reinforced concrete walls with minimum vertical reinforcement", Eng. Struct., vol. 143, pp. 330-345.
[http://dx.doi.org/10.1016/j.engstruct.2017.02.043]
]. The stress-strain relationships of concrete and reinforcing bars are shown in Figs. (5b) and (5c), respectively. It should be mentioned that since the shear capacity of concrete walls was significantly larger than the seismic demand, it was simulated as an elastic response.

Fig. (2)
3D view of the reference structures (a) 5 levels of parking (b) 3 levels of parking.


For the derivation of seismic fragility curves, the Incremental Dynamic Analysis (IDA) was used [24D. Vamvatsikos, and C.A. Cornell, "Incremental dynamic analysis", Earthquake Eng. Struct. Dynam., vol. 31, no. 3, pp. 491-514.
[http://dx.doi.org/10.1002/eqe.141]
]. A 0.75% stiffness-proportional Damping was used in the dynamic analysis [8A. Mwafy, "Analytically derived fragility relationships for the modern high-rise buildings in the UAE", Struct. Des. Tall Spec. Build., vol. 21, no. 11, pp. 824-843.
[http://dx.doi.org/10.1002/tal.642]
]. The hysteretic damping was accounted for in the fiber formulation of the inelastic frame elements. Considering the seismic hazard scenario of Malaysia, which is mainly affected by distant earthquakes, totally 15 far-field natural earthquake records were selected for the dynamic analysis. As it is shown in Fig. (6), the source-to-site distance of selected earthquake records ranges from 40 km to 379 km with a magnitude that ranges from 6.3 to 8.1. Table 1 provides more detail for the selected earthquake records.

Following the recommendation of ASCE 41 [22ASCE/SEI 41-13: Seismic evaluation and retrofit of existin buildings, american society of civil engineers, reston, virginia, 2014., ], three structural damage states were used in this study. Immediate Occupancy (IO) that represents minor damage, Life Safety (LS) that represents significant damage without collapse and Collapse Prevention (CP) in which the structure supports the gravity load but with no margin against collapse. The acceptance criteria for the above-mentioned damage states in concrete and reinforcing bars are shown in Table 2 [7M. Vafaei, and S.C. Alih, "Seismic vulnerability of air traffic control towers", Nat. Hazards, vol. 90, no. 2, pp. 803-822.
[http://dx.doi.org/10.1007/s11069-017-3072-3]
]. The acceptance criteria for the damage states of plastic hinges followed the recommended values in ASCE 41 [22ASCE/SEI 41-13: Seismic evaluation and retrofit of existin buildings, american society of civil engineers, reston, virginia, 2014., ].

Fig. (3)
Plan of the reference structures. (a) parking levels (b) residential levels.


Fig. (4)
Idealized 2D models of tall buildings (a) frame in axis A with 5 stories of parking (b) frame in axis B with 5 stories of parking (c) frame in axis A with 3 stories of parking (d) frame in axis B with 3 stories of parking.


Table 1
Detail of selected earthquake records.


Fig. (5)
Simulation of inelastic response of elements (a) moment-rotation relationships of plastic hinges (b) stress-strain relationship of concrete (c) stress-strain relationship of reinforcing bars.


Fig. (6)
Magnitude and source-to-site distance of employed earthquake records.


Table 2
Considered strain thresholds for concrete and reinforcements.


3. RESULTS AND DISCUSSION

3.1. Derivation of Seismic Fragility Curves

For the derivation of fragility curves the following equations were used [25Y.K. Wen, B.R. Ellingwood, and J.M. Bracci, Vulnerability function framework for consequence-based engineering, MAE Center Project DS-4 Report, University of Illinois, 2004, ]:

(1)
(2)
(3)

Where, P(DS|SI) is the conditional probability of exceeding the Damage State (DS) for the given seismic intensity (SI). π is the standard normal distribution; γC is the natural logarithm of the median of drift capacity for a particular damage state; γD|SI is the natural logarithm of calculated median demand drift given the seismic intensity from the best fit power law line. S2 is the standard error and Cov. is the coefficient of variation of the calculated limit State Capacities. ηD|SI stands for the demand uncertainty, while ηC and ηM reflect uncertainties related to the calculation of capacity and modelling errors, respectively. Following previous researches [8A. Mwafy, "Analytically derived fragility relationships for the modern high-rise buildings in the UAE", Struct. Des. Tall Spec. Build., vol. 21, no. 11, pp. 824-843.
[http://dx.doi.org/10.1002/tal.642]
] the value of ηM was taken as 0.3.

The obtained median inter-story drift capacities from IDA have been summarized in Table 3. It should be mentioned that IDA results indicated that there was a minimal margin between IO and CP limit states in the investigated frames. Therefore, as it can be seen from Table 3, no inter-story drift capacity was found for LS limit state. This is mainly because the structural elements were not designed and detailed for seismic actions. It can also be seen from the table that, regardless of the number of parking levels, the frames located at axis “A” have significantly larger drift capacities when compared with those located at axis “B”. Moreover, the increase in the number of parking levels has increased the CP drift capacity of the frame located at axis “A” and has decreased it for the frame located at axis “B”. It should be also mentioned that ASCE 41 [22ASCE/SEI 41-13: Seismic evaluation and retrofit of existin buildings, american society of civil engineers, reston, virginia, 2014., ] recommends 0.5%, 1%, and 2% of Inter-story Drift Ratios (IDRs) as the limit states for IO, LS and CP drift capacities. Therefore, the frames located at axis “B” have exhibited significantly smaller drift capacities for IO and CP limit states when compared with the recommended values by ASCE 41. The relationship between the median drift demand and peak ground acceleration (PGA) of investigated frame systems have been shown in Fig. (7). An excellent correlation can be seen between the PGAs and the median drift capacities of all frames. Therefore, for the derivation of seismic fragility curves, the PGA of ground motions was considered as the engineering demand parameter for the derivation of seismic fragility curves.

Fig. (7)
The relationship between the median drift demand and Peak Ground Acceleration (PGA) of investigated frame systems (a) frame at axis “A” with three levels of parking (b) frame at axis “B” with three levels of parking. (c) frame at axis “A” with 5 levels of parking (d) frame at axis “B” with 5 levels of parking.


The obtained seismic fragility curves for the frame with 3 and 5 levels of parking are depicted, respectively, in Fig. (8), and Fig. (9). It can be seen from Fig. (8) that the probability of exceeding the IO damage state for the frames located at axis “A” and “B” is almost similar. However, the probability of exceeding CP damage state for the frames located at axis “A” is significantly larger than the frame located at axis “B”. As can be seen from Fig. (9), for the building with 5 levels of parking the probability of exceeding the IO damage state for the frame located at axis “A” is larger than that of axis “B”. However, for small PGAs, the probability of exceeding the CP damage state in the frame located at axis “A” is smaller than the frame located at axis “B”. For large PGAs both frame exhibit almost similar probability of exceeding the CP damage state.

Fig. (8)
Seismic fragility curves for the frames with 3 levels of parking. (a) frame located at axis “A” (b) frame located at axis “B”.


Fig. (9)
Seismic fragility curves for the frames with 5 levels of parking. (a) frame located at axis “A” (b) frame located at axis “B”.


Table 3
Summary of the obtained median inter-story drift capacities.


Comparison between Fig. (8) and Fig. (9) shows that an increase in the number of parking levels increases the probability of exceeding the IO damage state in the frame located at axis “A” and decrease the probability of exceeding the IO damage state in the frame located in axis “B”. On the other hand, the increase in the number of parking levels decreases the probability of exceeding the CP damage state in the frame located at axis “A” and show an insignificant effect on the probability of exceeding the CP damage state in the frame located in axis “B”.

The maximum PGA of Kuala Lumpur city where the majority of tall concrete wall buildings have been constructed in Malaysia is 0.09g [26Malaysia National Annex to Eurocode 8: Design of structures for earthquake resistance - Part 1: General rules, seismic actions andrules for buildings, Department of standards Malaysia, 2017, ] on bedrock. Considering the soil effect, the PGA can reach 0.15g. Therefore, by using the obtained seismic fragility curves the maximum probability of exceeding the IO and CP damage states are 55% and 11%, respectively. This means that only repairable damage can be expected for the tall concrete wall buildings in Kula Lumpur. It can also be seen that the tall concrete wall buildings that have lesser parking levels exhibit a smaller probability of exceeding IO damage states for the exterior frames and a higher probability of exceeding IO damage states for the interior frames.

CONCLUSION

This study focused on the development of seismic fragility curves for tall concrete wall buildings in Malaysia. Two 25-story tall buildings with a similar plan but with a different number of parking levels were designed for gravity and wind loads. Then, a two-dimensional idealization was adopted to develop the fragility relationships of the buildings. For this purpose, an exterior and interior framing systems were selected from the designed buildings and fragility curves were derived for these frames. Inter-story drift capacities and demands were estimated using incremental dynamic analysis. Results indicated that for the Kuala Lumpur city where the majority of tall concrete wall buildings have been constructed the probability of exceeding the minor damage state was around 55%. However, the probability of exceeding severe damage state was around 11%. It was also found that buildings with a higher number of parking levels have a higher probability of exceeding the minor damage in their exterior frames and a lower probability of exceeding the minor damage in their interior frames.

CONSENT FOR PUBLICATION

Not applicable.

AVAILABILITY OF DATA AND MATERIALS

The data that support the findings of this study are available from the corresponding author (M.V.) on request.

FUNDING

This study was funded by the Ministry of Higher Education of Malaysia through the RUG votes of 17H80 and 19H36.

CONFLICT OF INTEREST

The authors declare no conflict of interest, financial or otherwise.

ACKNOWLEDGEMENTS

Authors would like to thank Universiti Teknologi Malaysia for their support.

REFERENCES

[1] S.C. Alih, and M. Vafaei, "Performance of reinforced concrete buildings and wooden structures during the 2015 Mw 6.0 Sabah earthquake in Malaysia", Eng. Fail. Anal., vol. 102, pp. 351-368.
[http://dx.doi.org/10.1016/j.engfailanal.2019.04.056]
[2] F. Cui, H. Zhang, M. Ghosn, and Y. Xu, "Seismic fragility analysis of deteriorating RC bridge substructures subject to marine chloride-induced corrosion", Eng. Struct., vol. 155, pp. 61-72.
[http://dx.doi.org/10.1016/j.engstruct.2017.10.067]
[3] C. Zhou, M. Tian, and K. Guo, "Seismic partitioned fragility analysis for high-rise RC chimney considering multidimensional ground motion", Struct. Des. Tall Spec. Build., vol. 28, no. 1, .e1568
[http://dx.doi.org/10.1002/tal.1568]
[4] L. Su, "Seismic fragility analysis of pile-supported wharves with the influence of soil permeability", Soil. Dyn. Earthquake Eng., vol. 122, pp. 211-227.
[http://dx.doi.org/10.1016/j.soildyn.2019.04.003]
[5] H. Sadraddin, S. Xiaoyun, and H. Yufeng, "Fragility assessment of high-rise reinforced concrete buildings considering the effects of shear wall contributions", The Struct. Des. Tall Spec. Build., vol. 24, p. 421-439.
[6] D. Gautam, G. Fabbrocino, and F. Santucci de Magistris, "Derive empirical fragility functions for Nepali residential buildings", Eng. Struct., vol. 171, pp. 617-628.
[http://dx.doi.org/10.1016/j.engstruct.2018.06.018]
[7] M. Vafaei, and S.C. Alih, "Seismic vulnerability of air traffic control towers", Nat. Hazards, vol. 90, no. 2, pp. 803-822.
[http://dx.doi.org/10.1007/s11069-017-3072-3]
[8] A. Mwafy, "Analytically derived fragility relationships for the modern high-rise buildings in the UAE", Struct. Des. Tall Spec. Build., vol. 21, no. 11, pp. 824-843.
[http://dx.doi.org/10.1002/tal.642]
[9] C-S.W. Yang, S.D. Werner, and R. DesRoches, "Seismic fragility analysis of skewed bridges in the central southeastern United States", Eng. Struct., vol. 83, pp. 116-128.
[http://dx.doi.org/10.1016/j.engstruct.2014.10.025]
[10] H.N. Phan, F. Paolacci, O.S. Bursi, and N. Tondini, "Seismic fragility analysis of elevated steel storage tanks supported by reinforced concrete columns", J. Loss Prev. Process Ind., vol. 47, pp. 57-65.
[http://dx.doi.org/10.1016/j.jlp.2017.02.017]
[11] A. Ghazali, H. Al-Haris Alaydrus, S.C. Alih, and M. Vafaei, "Seismic fragility of concrete box girder bridges in Malaysia", IOP Conf. Ser. Mater. Sci. Eng., vol. vol. 513, p. 012019.
[http://dx.doi.org/10.1088/1757-899X/513/1/012019]
[12] K.T. Tan, M. Suhatril, H.A. Razak, and D. Lu, "Seismic vulnerability of low- and mid-rise reinforced concrete buildings in malaysia designed by considering only gravity loads", Arab. J. Sci. Eng., vol. 43, no. 4, pp. 1641-1654.
[http://dx.doi.org/10.1007/s13369-017-2675-z]
[13] S.N.A. Saruddin, and F.M. Nazri, "Fragility curves for low- and mid-rise buildings in Malaysia", Procedia Eng., vol. 125, pp. 873-878.
[http://dx.doi.org/10.1016/j.proeng.2015.11.056]
[14] N. Amiera, M. Vafaei, and S.C. Alih, "Seismic fragility of low ductilefully infilled reinforced concrete frame in Malaysia", vol. 9. 2018, p.1-19,
[15] M.P. Berry, D.E. Lehman, and L.N. Lowes, "Lumped-plasticity models for performance simulation of bridge columns", ACI Struct. J., vol. 105, no. 3, .
[16] M. Vafaei, S. C. Alih, and Q. Abdul Rahman, "Drift demands of low-ductile moment resistance frames (MRF) under far field earthquake excitations", J. Teknol., vol. 78, no. 6, .
[http://dx.doi.org/10.11113/jt.v78.5076]
[17] R. Ahmadi, F.M. Nazri, K. Pilakoutas, R. Mulyani, and I. Hajirasouliha, "Seismic vulnerability assessment of an industrial building in peninsular Malaysia", 5th Brunei Int. Conf. Eng. Technol. (BICET 2014), pp. 307-313.
[http://dx.doi.org/10.1049/cp.2014.1124]
[18] ASCE/SEI 7-10, Minimum design loads for buildings and other structures, american society of civil engineers, reston, virginia, 2010,
[19] B. Standard, BS8110-1, "Structural use of concrete, code of practice for design and construction" part 1, 1997,
[20] CSI, ETABS. ‘V-16’: Integrated finite element analysis and design of structures basic analysis reference manual, Computers and StructuresInc, 2016,
[21] M. Vafaei, S. C. Alih, and A. Fallah, "The accuracy of the lumped plasticity model for estimating nonlinear behavior of reinforced concrete frames under gradually increasing vertical loads", Struct. Concr, .
[http://dx.doi.org/10.1002/suco.201800357]
[22] ASCE/SEI 41-13: Seismic evaluation and retrofit of existin buildings, american society of civil engineers, reston, virginia, 2014.,
[23] Y. Lu, and R.S. Henry, "Numerical modelling of reinforced concrete walls with minimum vertical reinforcement", Eng. Struct., vol. 143, pp. 330-345.
[http://dx.doi.org/10.1016/j.engstruct.2017.02.043]
[24] D. Vamvatsikos, and C.A. Cornell, "Incremental dynamic analysis", Earthquake Eng. Struct. Dynam., vol. 31, no. 3, pp. 491-514.
[http://dx.doi.org/10.1002/eqe.141]
[25] Y.K. Wen, B.R. Ellingwood, and J.M. Bracci, Vulnerability function framework for consequence-based engineering, MAE Center Project DS-4 Report, University of Illinois, 2004,
[26] Malaysia National Annex to Eurocode 8: Design of structures for earthquake resistance - Part 1: General rules, seismic actions andrules for buildings, Department of standards Malaysia, 2017,

Endorsements



"Open access will revolutionize 21st century knowledge work and accelerate the diffusion of ideas and evidence that support just in time learning and the evolution of thinking in a number of disciplines."


Daniel Pesut
(Indiana University School of Nursing, USA)

"It is important that students and researchers from all over the world can have easy access to relevant, high-standard and timely scientific information. This is exactly what Open Access Journals provide and this is the reason why I support this endeavor."


Jacques Descotes
(Centre Antipoison-Centre de Pharmacovigilance, France)

"Publishing research articles is the key for future scientific progress. Open Access publishing is therefore of utmost importance for wider dissemination of information, and will help serving the best interest of the scientific community."


Patrice Talaga
(UCB S.A., Belgium)

"Open access journals are a novel concept in the medical literature. They offer accessible information to a wide variety of individuals, including physicians, medical students, clinical investigators, and the general public. They are an outstanding source of medical and scientific information."


Jeffrey M. Weinberg
(St. Luke's-Roosevelt Hospital Center, USA)

"Open access journals are extremely useful for graduate students, investigators and all other interested persons to read important scientific articles and subscribe scientific journals. Indeed, the research articles span a wide range of area and of high quality. This is specially a must for researchers belonging to institutions with limited library facility and funding to subscribe scientific journals."


Debomoy K. Lahiri
(Indiana University School of Medicine, USA)

"Open access journals represent a major break-through in publishing. They provide easy access to the latest research on a wide variety of issues. Relevant and timely articles are made available in a fraction of the time taken by more conventional publishers. Articles are of uniformly high quality and written by the world's leading authorities."


Robert Looney
(Naval Postgraduate School, USA)

"Open access journals have transformed the way scientific data is published and disseminated: particularly, whilst ensuring a high quality standard and transparency in the editorial process, they have increased the access to the scientific literature by those researchers that have limited library support or that are working on small budgets."


Richard Reithinger
(Westat, USA)

"Not only do open access journals greatly improve the access to high quality information for scientists in the developing world, it also provides extra exposure for our papers."


J. Ferwerda
(University of Oxford, UK)

"Open Access 'Chemistry' Journals allow the dissemination of knowledge at your finger tips without paying for the scientific content."


Sean L. Kitson
(Almac Sciences, Northern Ireland)

"In principle, all scientific journals should have open access, as should be science itself. Open access journals are very helpful for students, researchers and the general public including people from institutions which do not have library or cannot afford to subscribe scientific journals. The articles are high standard and cover a wide area."


Hubert Wolterbeek
(Delft University of Technology, The Netherlands)

"The widest possible diffusion of information is critical for the advancement of science. In this perspective, open access journals are instrumental in fostering researches and achievements."


Alessandro Laviano
(Sapienza - University of Rome, Italy)

"Open access journals are very useful for all scientists as they can have quick information in the different fields of science."


Philippe Hernigou
(Paris University, France)

"There are many scientists who can not afford the rather expensive subscriptions to scientific journals. Open access journals offer a good alternative for free access to good quality scientific information."


Fidel Toldrá
(Instituto de Agroquimica y Tecnologia de Alimentos, Spain)

"Open access journals have become a fundamental tool for students, researchers, patients and the general public. Many people from institutions which do not have library or cannot afford to subscribe scientific journals benefit of them on a daily basis. The articles are among the best and cover most scientific areas."


M. Bendandi
(University Clinic of Navarre, Spain)

"These journals provide researchers with a platform for rapid, open access scientific communication. The articles are of high quality and broad scope."


Peter Chiba
(University of Vienna, Austria)

"Open access journals are probably one of the most important contributions to promote and diffuse science worldwide."


Jaime Sampaio
(University of Trás-os-Montes e Alto Douro, Portugal)

"Open access journals make up a new and rather revolutionary way to scientific publication. This option opens several quite interesting possibilities to disseminate openly and freely new knowledge and even to facilitate interpersonal communication among scientists."


Eduardo A. Castro
(INIFTA, Argentina)

"Open access journals are freely available online throughout the world, for you to read, download, copy, distribute, and use. The articles published in the open access journals are high quality and cover a wide range of fields."


Kenji Hashimoto
(Chiba University, Japan)

"Open Access journals offer an innovative and efficient way of publication for academics and professionals in a wide range of disciplines. The papers published are of high quality after rigorous peer review and they are Indexed in: major international databases. I read Open Access journals to keep abreast of the recent development in my field of study."