Table 2: Comparison Between the Quantitative Assessment of LV Volumes, Mass and Function by the 2D and the 3D Cine-MR Techniques

    Mean Difference Between Both Observers (Bias)    Coefficient of Repeatability
Parameter 2D 3D P* 2D 3D P**
LV EDV (ml) 0.5 8.3 0.06 ± 24.0 ± 17.1 0.32
LV ESV (ml) 0.2 6.6 0.05 ± 20.0 ± 9.0 0.03
LV SV (ml) 0.6 0 0.88 ± 21.4 ± 27.1 0.49
LV EF (%) 1.5 -2.4 0.05 ± 10.5 ± 8.9 0.65
LV mass (g) 13.8 14.6 0.85 ± 27.6 ± 12.7 0.03

* P value of the Student’s t test for the 2D versus the 3D mean differences (bias)

** P value of the two-sample variance-comparison test for the 2D versus 3D repeatability coefficients

LV denotes left ventricular; 2D, two-dimensional; 3D, three-dimensional; EDV, end-diastolic volume; ESV, end-systolic volume; SV, systolic volume; and EF, ejection fraction.