Table 4: Data obtained from the Titanium-Titanium group after immersion in artificial saliva.
Sample |
Sector |
Sa |
Sp |
Sv |
1 |
Abutment neck (U neck) |
0.075 |
1.48 |
1.178 |
|
Implant neck (I neck) |
0.071 |
2.141 |
3.927 |
|
Implant body (I body) |
0.342 |
4.836 |
10.087 |
2 |
Abutment neck (I neck) |
0.048 |
2.04 |
1.23 |
|
Implant neck (U neck) |
0.062 |
2.774 |
4.923 |
|
Implant body (I body) |
0.504 |
14.755 |
14.682 |
3 |
Abutment neck (U neck) |
0.046 |
1.097 |
6.274 |
|
Implant neck (I neck) |
0.051 |
2.512 |
0.93 |
|
Implant body (I body) |
0.486 |
10.274 |
10.177 |
4 |
Abutment neck (U neck) |
0.046 |
1.527 |
0.858 |
|
Implant neck (I neck) |
0.092 |
1.837 |
1.326 |
|
Implant body (I body) |
0.476 |
10.758 |
13.079 |
5 |
Abutment neck (U neck) |
0.058 |
1.251 |
1.282 |
|
Implant neck (I neck) |
0.06 |
0.907 |
0.997 |
|
Implant body (I body) |
0.565 |
6.804 |
12.324 |