Table 1: Diagnostic accuracy of ultrasonography and radiography for the detection of fractures in different areas.

Studied Area Sensitivity of Radiography
(%)
Specificity of Radiography (%) Accuracy of Radiography (%) Sensitivity of Sonography (%) Specificity of Sonography (%) Accuracy of Sonography (%) Reproducibility of Radiography (%) Reproducibility of Sonography (%) Correlation between Radiography and Sonography
Nasal cartilage 62.50 87.50 50.00 75.50 100 75.00 46.67 65.67 46.00
Nasal dorsum 75.00 100 75.00 50.00 87.00 37.00 84.64 44.62 66.62
Lateral nasal wall 75.00 87.50 62.50 75.00 87.50 62.50 87.10 73.00 90.00
Zygomatic arch 87.00 100.00 87.00 62.00 87.00 50.00 62.50 87.10 61.29