The Open Dentistry Journal




ISSN: 1874-2106 ― Volume 13, 2019

Recording the Tilt of a Cast on a Surveyor



Omid Savabi1, Farinaz Shirban2, *
1 Torabinejad Dental Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
2 Torabinejad Dental Research Center, Department of Orthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran

Abstract

Some patients are not satisfied with removable partial dentures (RPDs), when it is not stable during mastication.A dental surveyor can be used to prevent problems related to production of RPDs. Determining the best path of insertion and removal is an initial and fundamental step in RDPs planning. The path of insertion record enables the technician to reproducing the cast in the same position on a surveyor that the dentist selected. This article describes new method for this purpose that could be useful for recording and reproducing the tilt of casts.

Keywords: Partial dentures, surveyor, tilt.


Article Information


Identifiers and Pagination:

Year: 2015
Volume: 9
First Page: 174
Last Page: 175
Publisher Id: TODENTJ-9-174
DOI: 10.2174/1874210601509010174

Article History:

Received Date: 27/12/2014
Revision Received Date: 16/3/2015
Acceptance Date: 31/3/2015
Electronic publication date: 15 /5/2015
Collection year: 2015

Article Metrics:

CrossRef Citations:
0

Total Statistics:

Full-Text HTML Views: 1874
Abstract HTML Views: 1235
PDF Downloads: 448
Total Views/Downloads: 3557

Unique Statistics:

Full-Text HTML Views: 971
Abstract HTML Views: 702
PDF Downloads: 315
Total Views/Downloads: 1988
Geographical View

© Savabi and Shirban; Licensee Bentham Open.

open-access license: This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.


* Address correspondence to this author at the Torabinejad Dental Research Center, Department of Orthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran; Tel: 00983137922841; Fax: 00983136687080; E-mail: shirban123@yahoo.com





INTRODUCTION

Removable dental prosthesis (RDP) is a choice of treatment of partially edentulous patients when fixed dental prostheses or implant-supported restorations are contraindicated due to economic, technical and biologic concerns.

The cast may be returned to the surveyor for trimming block out on the master cast or locating clasp arms in relation to undercut areas [1Dumbrigue HB, Chingbingyong MI. A new method for recording and reproducing cast orientation on a survey table J Prosthet Dent 2003; 89: 76-8.]. Appropriate analysis of the cast is one of the important and essential steps in preparation of RDP [2Bezzon OL, Ribeiro RF, Pagnano VO. Device for recording the path of insertion for removable partial dentures J Prosthet Dent 2000; 84: 136-8.-4Wagner AG, Forgue EG. A study of four methods of recording the path of insertion of removable partial dentures J Prosthet Dent 1976; 35: 267-72.].

The clinician Surveys the diagnostic cast to design an adequate planning for RDP framework [5LaVere AM, Freda AL. A simplified procedure for survey and design of diagnostic casts J Prosthet Dent 1977; 37: 680-3.]. The path of insertion is determined with the surveyor regards to height of contours, guiding planes, interferences and esthetics for adequate retention, stability, support and esthetics for RDPs [3Coy RE, Arnold PD. Survey and design of diagnostic casts for removable partial dentures J Prosthet Dent 1974; 32: 103-6.].

The path of insertion should be recorded on the diagnostic cast in order to be transferred into the definitive or working cast. Also the path of insertion record enables the technician to reproducing the cast in the same position on a surveyor that the dentist selected.

Traditional methods only allow repositioning of the cast on characters, which have been placed; but, accurate reproducing of this cast or the other casts such as duplicated casts on the surveyor may be difficult [1Dumbrigue HB, Chingbingyong MI. A new method for recording and reproducing cast orientation on a survey table J Prosthet Dent 2003; 89: 76-8.].

There are several methods for recording the tilt of a cast in surveyor [6Carr AB, McGivney GP, Brown DT, Eds. McCracken's removable partial prosthodontics 11th ed StLouis Mosby. 2005; pp. 177-8.-9Kamble VD1, Parkhedkar RD. Reorientation simplified a device for recording and reproducing the path of insertion for removable partial dentures Indian J Dent Res 2014; 25: 260-.].

Conventional method for recording the cast orientation includes tripodization method, to establish a plane of orientation with this method several areas on the cast needed and horizontal marks are placed on three divergent anatomic areas of the cast. Another method is the scoring method. In this method three vertical marks are made along the base of the cast on the posterior and lateral sides [10Phoenix RD, Cagna DR, DeFreest CF, Stewart KL, Eds. Stewart's clinical removable partial prosthodontics 4th ed Hanover Park Quintessence. 2008; pp. 218-0.]. The analyzing rod of the surveyor is aligned with all three marks for reproduction of the cast. These methods allow reproduction of the cast on marks, which have been placed; however, correct reproduction of this cast or the other casts such as duplicated casts on the surveyor may be sometimes difficult [11Dumbrigue HB, Chingbingyong MI. A new method for recording and reproducing cast orientation on a survey table J Prosthet Dent 2003; 89: 76-8.].

Shakibamehr, et al. identified a method with using acrylic resin index, thereby shrinking the acrylic resin may result in inaccurate adaption of the acrylic index on the teeth occlusal surfaces [12Shakibamehr AH, Askari N, Abolhasani M, Moradpoor H, Nejatidanesh F. A procedure for recording and reproducing the cast position on a surveyor Dent Res J (Isfahan) 2013; 10: 695-.].

This article describes another method for this purpose that could be useful for recording and reproducing the tilt of casts.

MATERIALS AND METHODS

This article describes an effective method for recording the cast orientation on the surveyor table and reproducing this orientation to other casts using an additional constructed device.

1. Gradate the surveyor spindle into millimeters degrees (Fig. 1).

Fig. (1)

Surveyor spindle with millimeters degrees.



Fig. (2)

Each screw touches a point on the cast.



2. Attach three narrow strips (Vanguard, Kuala Lumpur, Malaysia) two (short) with 5 and one (long) with 7 holes from one side to a hand-piece mandrel (Sunva, Jiangsu, China) (Fig. 2).

3. Attach a screw and nut (Vanguard, Kuala Lumpur, Malaysia) to the other ending holes of two short narrow strips.

4. Fasten the mandrel screw in the surveyor spindle.

5. Adjust the two short narrow strips until screws touch two points on the cast.

6. Place a screw in a hole in the long narrow strip where the screw touches another point on the cast (Fig. 2).

7. Relate each point on the cast to corresponding narrow strips and record this relation in the patient file.

8. Record the length of the surveyor spindle from surveyor gradation and the hole that used in long narrow strip.

9. Set the recording device and surveyor spindle to the correct lengths.

10. Change the tilt of the cast until all screws touch the points on the cast.

DISCUSSION

The advantages of this method include accurate reproducing of diagnostic cast, duplicated or definitive cast on the surveyor with the same recording device.

Tripodization and scoring methods need major working time, they are not accurate and only useful for reproducing the tilt of the cast that the tilt of it recorded. Shakibamehr, et al. identified a method with using acrylic resin index, thereby shrinking the acrylic resin which may result in inaccurate adaption of the acrylic index on the teeth occlusal surfaces [12Shakibamehr AH, Askari N, Abolhasani M, Moradpoor H, Nejatidanesh F. A procedure for recording and reproducing the cast position on a surveyor Dent Res J (Isfahan) 2013; 10: 695-.].

Need for additional device and time for constriction of the device are disadvantages of our method. More studies are needed to evaluate and compare the accuracy of available techniques.

CONCLUSION

The reproduction of the casts on the surveyor can be performed rapidly on duplication, definitive casts or when new analysis is required . This method allows for the precise reproducing of the path of insertion for the patient.

CONFLICT OF INTEREST

The authors confirm that this article content has no conflict of interest.

ACKNOWLEDGEMENTS

Declared none.

REFERENCES

[1] Dumbrigue HB, Chingbingyong MI. A new method for recording and reproducing cast orientation on a survey table J Prosthet Dent 2003; 89: 76-8.
[2] Bezzon OL, Ribeiro RF, Pagnano VO. Device for recording the path of insertion for removable partial dentures J Prosthet Dent 2000; 84: 136-8.
[3] Coy RE, Arnold PD. Survey and design of diagnostic casts for removable partial dentures J Prosthet Dent 1974; 32: 103-6.
[4] Wagner AG, Forgue EG. A study of four methods of recording the path of insertion of removable partial dentures J Prosthet Dent 1976; 35: 267-72.
[5] LaVere AM, Freda AL. A simplified procedure for survey and design of diagnostic casts J Prosthet Dent 1977; 37: 680-3.
[6] Carr AB, McGivney GP, Brown DT, Eds. McCracken's removable partial prosthodontics 11th ed StLouis Mosby. 2005; pp. 177-8.
[7] Kaloyannides TM. Reproduction of tilt of a cast on a surveyor J Prosthet Dent 1973; 30: 465-7.
[8] Steas AD. Recording and reproducing the tilt of a cast on a surveyor J Prosthet Dent 1987; 57: 121-5.
[9] Kamble VD1, Parkhedkar RD. Reorientation simplified a device for recording and reproducing the path of insertion for removable partial dentures Indian J Dent Res 2014; 25: 260-.
[10] Phoenix RD, Cagna DR, DeFreest CF, Stewart KL, Eds. Stewart's clinical removable partial prosthodontics 4th ed Hanover Park Quintessence. 2008; pp. 218-0.
[11] Dumbrigue HB, Chingbingyong MI. A new method for recording and reproducing cast orientation on a survey table J Prosthet Dent 2003; 89: 76-8.
[12] Shakibamehr AH, Askari N, Abolhasani M, Moradpoor H, Nejatidanesh F. A procedure for recording and reproducing the cast position on a surveyor Dent Res J (Isfahan) 2013; 10: 695-.

Endorsements



"Thank you for your magnificent and marvelous support throughout the publication stages. I would like to endorse my experience with you as a Junior Researcher and a recent graduate of the Dental school. Once again Thank you for your Great Help and Guidance throughout the stages of Publication. You guys are a great team and I am proud to be a Young Bentham author."


Asra Sabir Hussain
The University of Edinburgh Business School, UK

"My experience with Bentham Open was a valuable one because the quality of the services and analysis of my paper contributed in improving what we intended to convey to the readers."


José Ricardo Kina
Department of Surgery and Integrated Clinic,
Araçatuba School of Dentistry, São Paulo State University
Brazil

"The Publication Manager was very cooperative and replied my mails and guided me without any delays; however the reviewing process was too long."


Mahtab Memarpour
Prevention of Oral and Dental Disease Research Center,
Department of Pediatric Dentistry, School of Dentistry,
Shiraz University of Medical Sciences, Shiraz,
Iran


Browse Contents




Webmaster Contact: info@benthamopen.net
Copyright © 2019 Bentham Open