Table 1: Overview of the Most Frequently Used Insulin Sensitivity Tests

  Accuracy Time Demand (Hours) Notes References
Intra- Subject CV Correlation to Gold Standard Clinician Participant
EIC 4 to 10% Gold standard 10 4 Results is not guaranteed with an inexperienced clinician  ADDIN EN.CITE  ADDIN EN.CITE.DATA [5, 6, 11]
IVGTT 21% 0.44 to 0.89 3-5 3-5 Result generally requires a complex computerised solver  ADDIN EN.CITE  ADDIN EN.CITE.DATA [8, 12, 13]
OGTT 7 to 15% 0.6 to 0.8 3-4 3-4 Rate of appearance of glucose in plasma is relatively unknown  ADDIN EN.CITE  ADDIN EN.CITE.DATA [5, 14, 15]
2hr-OGTT 15 to 40% 0.45 to 0.74 0.5 2.5 Poor repeatability in terms of re-classification rate  ADDIN EN.CITE  ADDIN EN.CITE.DATA [7, 14, 16]
HOMA 10 to 40% -0.6 to -0.9 0.25 0.25 Low resolution in region of clinical significance  ADDIN EN.CITE  ADDIN EN.CITE.DATA [5, 17, 18]

Shown are the assessed accuracies in coefficient of variation (CV=SD/mean) and correlation to the gold standard EIC; and the time demand in hours for the clinician and the participant.