Table 2: Published study results of open ankle arthrodesis using a hybrid technique.

Study
year
Authors Patients
n
Type of Arthrodesis Follow-up
Months
Fusion
Rate %
Infection
Rate %
Revision
Rate %
2006 Kakarala 11 Screws + non-locking plate 26.8 100 Not given Not given
2017 Mitchell 39 Compression screw + anterior locking plate 17 92.3 5.2 2.6
2017 Prissel 46 Lag screw + anterior locking plate 9 97.9 8.5 2.1
2019 Own study 20 Compression screw + anterior locking plate 18 100 0 0