Table 2: Minimum and Maximum Anatomical Data for the Tibial Slope (Φtf ) [15] and Patellar Tendon Line of Force (Φpat) [16] are Reported with the Corresponding Maximum ACL Tension (FaclMAX) in Body Weight, Maximum Patellar Tendon Shear Force (FptMAX) in Body Weight, Maximum Tibio-Femoral Shear Contact Force (FtfMAX) Body Weight, As Well As the Percent Changes in these Maximum Model Outputs from the Control Values. Control Anatomical and Activation Parameters Values were from Kernozek and Ragan [7]

Control Tibial Slope (Φtf) Patellar Tendon Line of Force (Φpat)
Minimum Maximum Minimum Maximum
Parameter input value 1.0° 15.8° 10° 20°
FaclMAX 0.2563 0 0.7066 0.07234 0.4823
Percent change in FaclMAX -100% 176% -72% 88%
Fpt 0.3298 0.7509 -0.24 0.122 0.5397
Percent change in FptMAX 128% -173% -63% 64%
Ftf 1.056 0.1208 2.122 1.034 1.046
Percent change in FtfMAX -89% 101% -2% -1%