Table 3: Total Energy Loss for an Ideal Operation

S/N Pipe length, km Heat loss, KJ/s S/N Pipe length, km Heat loss, KJ/s
1 1 1.73E+08 29 29 1.22E+08
2 2 1.71E+08 30 30 1.22E+08
3 3 1.68E+08 31 31 118511341.7
4 4 1.66E+08 32 32 116946261.9
5 5 1.64E+08 33 33 115395061.2
6 6 1.63E+08 34 34 113857584.6
7 7 1.61E+08 35 35 112333735.0
8 8 1.59E+08 36 36 110823366.9
9 9 1.57E+08 37 37 109326383.3
10 10 1.55E+08 38 38 107842667.9
11 11 1.53E+08 39 39 106372055.8
12 12 1.51E+08 40 40 104914508.1
13 13 1.49E+08 41 41 103469840.7
14 14 1.47E+08 42 42 102037975.9
15 15 1.46E+08 43 43 100618797.2
16 16 1.44E+08 44 44 99212207.9
17 17 1.42E+08 45 45 97818042.8
18 18 1.40E+08 46 46 96436234.2
19 19 1.38E+08 47 47 95066656.0
20 20 1.37E+08 48 48 93709230.6
21 21 1.35E+08 49 49 92363812.4
22 22 1.33E+08 50 50 91030304.6
23 23 1.32E+08 51 51 89708600.3
24 24 1.30E+08 52 52 88398631.8
25 25 1.28E+08 53 53 87100234.2
26 26 1.27E+08 54 54 85813339.4
27 27 1.25E+08 55 55 84537850.7
28 28 1.23E+08