Editorial : The Issues Related to Hemodialysis Catheter Lock Prophylaxis with Recombinant Tissue Plasminogen Activator



Anil K. Saxena* , 1, Kenneth Abreo2, Tushar Vachharajani3
1 Al-Rahba hospital- Johns Hopkins Medicine International, Abu Dhabi, United Arab Emirates (UAE)
2 LSU Health Sciences Center, Shreveport, LA 71130, USA
3 Wake Forest University School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157, USA


Article Information


Identifiers and Pagination:

Year: 2011
Volume: 4
First Page: 9
Last Page: 11
Publisher Id: TOUNJ-4-9
DOI: 10.2174/1874303X01104010009

Article History:

Received Date: 7/4/2011
Revision Received Date: 25/5/2011
Acceptance Date: 26/5/2011
Electronic publication date: 5/7/2011

Licensee Bentham Open

open-access license: This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.


* Address correspondence to this author at the Nephrology Division, Department of Medicine, Al-Rahba hospital- Johns Hopkins Medicine International, PO Box 34555, Health Authority Abu Dhabi, Abu Dhabi, United Arab Emirates (UAE); Tel: (+971) 506370180; Fax: (+971) 2- 5064000; dranil_31982@yahoo.com





Arteriovenous fistulas (AVF) are the most preferred and promoted form of dialysis access due to their lowest complication rates. However, the changing demographic profile of end- stage renal disease (ESRD) with an increasing elderly and diabetic population having relatively poor vasculature, relative lack of prudent pre-ESRD planning for AV fistula creation, late referrals, and comparatively lower fistula maturation rates, are essentially the factors accountable for our continued dependence upon central venous catheters (CVCs) [1Schwab SJ, Beathard G. The hemodialysis catheter conundrum: Hate living with them, but can’t live without them Kidney Int 1999; 56: 1-17.-3Saxena AK, Panhotra BR. Prevention of catheter-related bloodstream infections: an appraisal of developments in designing an infection-resistant 'dream dialysis-catheter' Nephrology 2005; 10: 240-8.]. Moreover, CVCs remain the only means to provide instant access to the circulation during emergency situations arising from the unpredictable course of chronic kidney disease.

Virchow's described three broad categories of factors that contribute to thrombus formation -hypercoagulability, stasis and vascular endothelial injury. The placement of this relatively large foreign body traumatizes the host vessel and significantly alters hemodynamics fulfilling Virchow’s triad for thrombus formation and provides a nidus for bacterial entry into the circulation. However, catheter malfunction limits the life span of CVCs. Inadequate blood flow and catheter-related bloodstream infections (CRBSI) are common causes of recurrent use of thrombolytic therapy, antibiotics and often result in catheter removal. Generally, standard heparin (5000 U/ mL) is used to lock the CVCs to maintain catheter patency during the interdialytic period. Locking with heparin however, does not prevent bacterial colonization and subsequent development of CRBSI. Moreover, in vitro studies have shown that heparin may induce biofilm formation [4Diskin CJ, Stokes TJ, Dansby L, Radcliff L, Carter TB. Catheter locks, heparin and biofilm: what is the risk? Nephrol Dial Transplant 2008; 23(8): 2708-9.].

Replacing heparin with recombinant tissue plasminogen activator (rt-PA) once a week, as a dialysis catheter locking solution significantly reduced the incidence of catheter malfunction and CRBSI in a well conducted multicenter, double-blind, randomized controlled trial from Canada by Hemmelgarn and colleagues [5Hemmelgarn BR, Moist LM, Lok CE, et al. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator N Engl J Med 2011; 364: 303-12.]. The authors were able to decrease the rates of catheter malfunction by 50% and CRBSI by two-thirds, with the use of rt-PA once a week at a dose 1 mg per lumen. Patients (n=115) were randomly assigned to a catheter-locking group with heparin (5,000 U/mL) three times a week or with rt-PA (1 mg per lumen) substituted for heparin once a week and heparin used the remaining two times (n=110). Mean follow-up period after randomization was six months with treatment assignments concealed from patients, investigators, and trial staff. The primary outcome was catheter malfunction, and the secondary outcome was CRBSI.

In the rt-PA group, 20% (22/115) patients reached the primary outcome, compared with 34.8% (40/110) in the heparin group. CRBSI occurred in 5 (4.5%) patients in the rt-PA group and 15 (13.0%) patients in the heparin group. The risk for adverse events was similar (70% and 68.7%) in the rt-PA and heparin groups, respectively with no statistically significant difference in the serious adverse events between the two groups (20.9 % and 29.6%). Also, patients in the rt-PA group did not have a higher frequency and severity of bleeding episodes [5Hemmelgarn BR, Moist LM, Lok CE, et al. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator N Engl J Med 2011; 364: 303-12.].

This landmark study has received a lot of attention from experts in the field, as the results are very encouraging from the viewpoint of the prevention of CRBSI. The results are comparable to the outcomes reported in earlier trials involving antimicrobial locking solutions for the prevention of CRBSI among hemodialysis (HD) patients [6Dogra GK, Herson H, Hutchison B, et al. Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomized controlled study J Am Soc Nephrol 2002; 13: 2133-9.-2US Renal Data System. USRDS 2004 Annual Data Report Am J Kidney Dis 2005; 45: S8-S280.] (Fig. 1). However, the following issues merit further considerations.

Fig. (1)

Randomized controlled trials showing 60 to100 percent reductions in hemodialysis catheter related bloodstream infections (CRBSI).



The first issue is the definition of catheter malfunction. Hemodialysis catheters considered dysfunctional as per K/DOQI guidelines if the delivered blood flow is less than 300ml/min. Currently available catheters are designed to provide blood flow of 400ml/min. The catheters are used as a bridging access until the permanent access is mature enough and the maturation time is often unpredictable. Besides the blood flow, the solute clearance needs to be included in the definition of catheter malfunction although reduced solute clearance could be the consequence of reduced blood flow. In the short-term, the formation of clots in and around the catheter, as well as fibrin sheath formation, leads to catheter dysfunction-a common complication of the HD catheter that further leads to the inability to deliver adequate dialysis.

Catheter malfunction is a broader term and has been defined differently by different authors. Definitions include - a blood flow ranging from 200 mL/ minute or less for a single session of dialysis, 250 mL/minute during two successive dialysis treatments, to less than 300 mL/ minute for any dialysis session and alternatively, inability to initiate dialysis [13Clinical Practice Guidelines for Vascular Access - Vascular Access Work Group Am J Kidney Dis 2006; 48: S248-73., 14Rushing J. Caring for a patient's vascular access for hemodialysis Nurs Manage 2010; 41(10): 47.]. In the latter situation catheter replacement remains the sole option whereas in the former thrombolytic therapy may temporarily improve blood flow. Thus catheter removal appears to be a clinically more definitive marker of catheter malfunction than the peak blood flow. It appears that the optimal primary outcome obviously would have been the removal of the catheter, but the authors probably were concerned that they would not be able to enroll patients if they waited until catheters were removed due to malfunction. However, the hemodialysis guidelines actually define catheter malfunction on the basis of peak blood flow rather than the need for catheter replacement. Thus, the issue remains a matter of future debate.

Second, Hemmelgarn et al. have inadvertently raised an interesting issue concerning the possible mechanism whereby rt-PA lock prophylaxis could cause significant reductions in CRBSIs (1.37 vs 0.40 per 1000 catheter - days, P = 0.02) [5Hemmelgarn BR, Moist LM, Lok CE, et al. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator N Engl J Med 2011; 364: 303-12.]. A plausible explanation probably lies in the fact that catheter malfunction is frequently related to fibrin sheath or luminal clot formation. Fibrin, fibrinogen and fibronectin present in the thrombus enhance adherence of invading planktonic ‘slime’ producing bacteria, on the luminal surface of CVCs. This facilitates bacterial colonization and biofilm formation. Biofilms provide a protected environment for microorganisms for their multiplication and growth with their eventual discharge into the bloodstream causing CRBSI [3Saxena AK, Panhotra BR. Prevention of catheter-related bloodstream infections: an appraisal of developments in designing an infection-resistant 'dream dialysis-catheter' Nephrology 2005; 10: 240-8., 15Saxena AK. CVC: relationship between infection and thrombosis J Vasc Access 2010; 11: S33., 16Mehall JR, Saltzman DA, Jackson RJ, Smith SD. Fibrin sheath enhances central venous catheter infection Crit Care Med 2002; 30: 908-12.] (Fig. 2).

Fig. (2)

Mechanism of action of tissue plasminogen activator: Tissue plasminogen activator catalyzes the conversion of plasminogen to plasmin, which then cleaves fibrin into fibrin degradation products (FDP) to dissolve the thrombus and thus prevents bacterial adherence to the catheter luminal surface.



Raad et al. demonstrated a close relationship between thrombotic and infectious complications of CVCs with CRBSI rates significantly higher among patients with CVC - thrombosis than in those without clot in a 16 month follow up study (22.5 % vs 0.0%, P < 0.01) [17Raad II, Luna M, Khalil SA, et al. The relationship between the thrombotic and infectious complications of central venous catheters JAMA 1994; 271: 1014-6.]. A monthly rt-PA instillation reduced CRBSI episodes in patients with hemophilia; supporting the concept that thrombolysis could prevent CRBSI [18Weck S, Cheung S, Hiraoka-Sutow M, Patapoff T, Semba CP. Alteplase as a catheter locking solution: in vitro evaluation of biochemical stability and antimicrobial properties J Vasc Interv Radiol 2005; 16 (3): 379-83.]. Moreover, another study demonstrated inhibition of staphylococcal bacterial growth by Urokinase-type plasminogen activator which acted as an endogenous antibiotic [19Jin T, Bokarewa M, Tarkowski A. Urokinase-type plasminogen activator, an endogenous antibiotic J Infect Dis 2005; 192 (3): 429-37.].

The third issue is regarding the safety of rt-PA lock prophylaxis in the light of current evidence of the exit of catheter lock solutions into the circulation. Sungur et al, in their in-vitro studies performed on double lumen dialysis catheters, demonstrated a substantial amount of leak even when the corresponding catheter 'lock' volumes were used. Some catheters had lower leak ratios than the others, depending upon the size, filling volume and design [20Sungur M, Eryuksel E, Yavas S, Bihorac A, Layon AJ, Caruso L. Exit of catheter lock solutions from double lumen acute hemodialysis catheters--an in vitro study Nephrol Dial Transplant 2007; 22(12): 3533-7.]. The leak ratio increased significantly with 20% overfill and leakage persisted even when 'lock' volume of 20% less than the manufacturer stated catheter volume, was used. Currently, the amount of leak has been found to be clinically important in explaining the bleeding episodes reported after heparin lock placement [21Polaschegg HD, Shah C. Overspill of catheter locking solution: safety and efficacy aspects ASAIO J 2003; 49: 713-5.]. Likewise, 0.2 ml overfill of the stated catheter volume of gentamicin lock solution, led to plasma ‘drug’ concentrations close to toxic levels in an Australian study [6Dogra GK, Herson H, Hutchison B, et al. Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomized controlled study J Am Soc Nephrol 2002; 13: 2133-9.].

In the study of Hemmelgarn et al, the risk for adverse events was similar between the two groups; 70% of patients in the rt-PA group and 68.7% of patients in the heparin group had an adverse event, while reported serious adverse events were 20.9 % and 29.6% in rt-PA and heparin group, respectively [5Hemmelgarn BR, Moist LM, Lok CE, et al. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator N Engl J Med 2011; 364: 303-12.]. Likewise, patients in the rt-PA group did not have a higher frequency of bleeding episodes. However, regardless of the reported fact that there were no statistically significant differences between the two groups nearly one fifth of the patients in rt-PA group and almost one third in the heparin group, developed serious adverse events in the study with a short follow-up period of 6 months. This area warrants further long-term studies to investigate the impact of locking hemodialysis catheters with rt-PA in the light of recent reports on the exit of locking solutions in significant proportions, into the circulation – immediately after instillation and during the interdialytic period.

However, the lower likelihood of emergence of bacterial resistance could be one of the potential advantages of using rt-PA catheter lock prophylaxis. The trial sets a milestone and provides the first round findings on the new role of rt-PA in the prevention of hemodialysis catheter malfunction while setting the stage for more prospective randomized trials in this field to ascertain the efficacy and address the safety issues related to rt-PA.

REFERENCES

[1] Schwab SJ, Beathard G. The hemodialysis catheter conundrum: Hate living with them, but can’t live without them Kidney Int 1999; 56: 1-17.
[2] US Renal Data System. USRDS 2004 Annual Data Report Am J Kidney Dis 2005; 45: S8-S280.
[3] Saxena AK, Panhotra BR. Prevention of catheter-related bloodstream infections: an appraisal of developments in designing an infection-resistant 'dream dialysis-catheter' Nephrology 2005; 10: 240-8.
[4] Diskin CJ, Stokes TJ, Dansby L, Radcliff L, Carter TB. Catheter locks, heparin and biofilm: what is the risk? Nephrol Dial Transplant 2008; 23(8): 2708-9.
[5] Hemmelgarn BR, Moist LM, Lok CE, et al. Prevention of dialysis catheter malfunction with recombinant tissue plasminogen activator N Engl J Med 2011; 364: 303-12.
[6] Dogra GK, Herson H, Hutchison B, et al. Prevention of tunneled hemodialysis catheter-related infections using catheter-restricted filling with gentamicin and citrate: a randomized controlled study J Am Soc Nephrol 2002; 13: 2133-9.
[7] McIntyre CW, Hulme LJ, Taal M, Fluck RJ. Locking of tunneled hemodialysis catheters with gentamicin and heparin Kidney Int 2004; 66: 801-5.
[8] Nori US, Manoharan A, Yee J, Besarab A. Comparison of low-dose gentamicin with minocycline as catheter lock solutions in the prevention of catheter-related bacteremia Am J Kidney Dis 2006; 48: 596-605.
[9] Kim SH, Song KI, Chang JW, et al. Prevention of uncuffed hemodialysis catheter-related bacteremia using an antibiotic lock technique: a prospective, randomized clinical trial Kidney Int 2006; 69: 161-4.
[10] Saxena AK, Panhotra BR, Sundaram DS, et al. Tunneled catheters' outcome optimization among diabetics on dialysis through antibiotic-lock placement Kidney Int 2006; 70: 1629-35.
[11] Betjes MGH, van Agteren M. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution Nephrol Dial Transplant 2004; 19: 1546-51.
[12] Weijmer MC, van den Dorpel MA, Van de Ven PJ, et al. CITRATE Study Group. Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheter-locking solution in hemodialysis patients J Am Soc Nephrol 2005; 16(9): 2769-77.
[13] Clinical Practice Guidelines for Vascular Access - Vascular Access Work Group Am J Kidney Dis 2006; 48: S248-73.
[14] Rushing J. Caring for a patient's vascular access for hemodialysis Nurs Manage 2010; 41(10): 47.
[15] Saxena AK. CVC: relationship between infection and thrombosis J Vasc Access 2010; 11: S33.
[16] Mehall JR, Saltzman DA, Jackson RJ, Smith SD. Fibrin sheath enhances central venous catheter infection Crit Care Med 2002; 30: 908-12.
[17] Raad II, Luna M, Khalil SA, et al. The relationship between the thrombotic and infectious complications of central venous catheters JAMA 1994; 271: 1014-6.
[18] Weck S, Cheung S, Hiraoka-Sutow M, Patapoff T, Semba CP. Alteplase as a catheter locking solution: in vitro evaluation of biochemical stability and antimicrobial properties J Vasc Interv Radiol 2005; 16 (3): 379-83.
[19] Jin T, Bokarewa M, Tarkowski A. Urokinase-type plasminogen activator, an endogenous antibiotic J Infect Dis 2005; 192 (3): 429-37.
[20] Sungur M, Eryuksel E, Yavas S, Bihorac A, Layon AJ, Caruso L. Exit of catheter lock solutions from double lumen acute hemodialysis catheters--an in vitro study Nephrol Dial Transplant 2007; 22(12): 3533-7.
[21] Polaschegg HD, Shah C. Overspill of catheter locking solution: safety and efficacy aspects ASAIO J 2003; 49: 713-5.
Society Affiliation


Track Your Manuscript:


Endorsements



"Open access will revolutionize 21st century knowledge work and accelerate the diffusion of ideas and evidence that support just in time learning and the evolution of thinking in a number of disciplines."


Daniel Pesut
(Indiana University School of Nursing, USA)

"It is important that students and researchers from all over the world can have easy access to relevant, high-standard and timely scientific information. This is exactly what Open Access Journals provide and this is the reason why I support this endeavor."


Jacques Descotes
(Centre Antipoison-Centre de Pharmacovigilance, France)

"Publishing research articles is the key for future scientific progress. Open Access publishing is therefore of utmost importance for wider dissemination of information, and will help serving the best interest of the scientific community."


Patrice Talaga
(UCB S.A., Belgium)

"Open access journals are a novel concept in the medical literature. They offer accessible information to a wide variety of individuals, including physicians, medical students, clinical investigators, and the general public. They are an outstanding source of medical and scientific information."


Jeffrey M. Weinberg
(St. Luke's-Roosevelt Hospital Center, USA)

"Open access journals are extremely useful for graduate students, investigators and all other interested persons to read important scientific articles and subscribe scientific journals. Indeed, the research articles span a wide range of area and of high quality. This is specially a must for researchers belonging to institutions with limited library facility and funding to subscribe scientific journals."


Debomoy K. Lahiri
(Indiana University School of Medicine, USA)

"Open access journals represent a major break-through in publishing. They provide easy access to the latest research on a wide variety of issues. Relevant and timely articles are made available in a fraction of the time taken by more conventional publishers. Articles are of uniformly high quality and written by the world's leading authorities."


Robert Looney
(Naval Postgraduate School, USA)

"Open access journals have transformed the way scientific data is published and disseminated: particularly, whilst ensuring a high quality standard and transparency in the editorial process, they have increased the access to the scientific literature by those researchers that have limited library support or that are working on small budgets."


Richard Reithinger
(Westat, USA)

"Not only do open access journals greatly improve the access to high quality information for scientists in the developing world, it also provides extra exposure for our papers."


J. Ferwerda
(University of Oxford, UK)

"Open Access 'Chemistry' Journals allow the dissemination of knowledge at your finger tips without paying for the scientific content."


Sean L. Kitson
(Almac Sciences, Northern Ireland)

"In principle, all scientific journals should have open access, as should be science itself. Open access journals are very helpful for students, researchers and the general public including people from institutions which do not have library or cannot afford to subscribe scientific journals. The articles are high standard and cover a wide area."


Hubert Wolterbeek
(Delft University of Technology, The Netherlands)

"The widest possible diffusion of information is critical for the advancement of science. In this perspective, open access journals are instrumental in fostering researches and achievements."


Alessandro Laviano
(Sapienza - University of Rome, Italy)

"Open access journals are very useful for all scientists as they can have quick information in the different fields of science."


Philippe Hernigou
(Paris University, France)

"There are many scientists who can not afford the rather expensive subscriptions to scientific journals. Open access journals offer a good alternative for free access to good quality scientific information."


Fidel Toldrá
(Instituto de Agroquimica y Tecnologia de Alimentos, Spain)

"Open access journals have become a fundamental tool for students, researchers, patients and the general public. Many people from institutions which do not have library or cannot afford to subscribe scientific journals benefit of them on a daily basis. The articles are among the best and cover most scientific areas."


M. Bendandi
(University Clinic of Navarre, Spain)

"These journals provide researchers with a platform for rapid, open access scientific communication. The articles are of high quality and broad scope."


Peter Chiba
(University of Vienna, Austria)

"Open access journals are probably one of the most important contributions to promote and diffuse science worldwide."


Jaime Sampaio
(University of Trás-os-Montes e Alto Douro, Portugal)

"Open access journals make up a new and rather revolutionary way to scientific publication. This option opens several quite interesting possibilities to disseminate openly and freely new knowledge and even to facilitate interpersonal communication among scientists."


Eduardo A. Castro
(INIFTA, Argentina)

"Open access journals are freely available online throughout the world, for you to read, download, copy, distribute, and use. The articles published in the open access journals are high quality and cover a wide range of fields."


Kenji Hashimoto
(Chiba University, Japan)

"Open Access journals offer an innovative and efficient way of publication for academics and professionals in a wide range of disciplines. The papers published are of high quality after rigorous peer review and they are Indexed in: major international databases. I read Open Access journals to keep abreast of the recent development in my field of study."


Daniel Shek
(Chinese University of Hong Kong, Hong Kong)

"It is a modern trend for publishers to establish open access journals. Researchers, faculty members, and students will be greatly benefited by the new journals of Bentham Science Publishers Ltd. in this category."


Jih Ru Hwu
(National Central University, Taiwan)


Browse Contents



Table of Contents


Webmaster Contact: info@benthamopen.net
Copyright © 2021 Bentham Open