Table 3: Energy exchange in various equipments.

Equipment Power consumed or delivered
Pitting machine W= 12.50 kW
Belt conveying (P-1/BC) W= 9.07 kW
Grinding (P-4/GR) W=90.71 kW
Agitation (P-5/Extract) Rme =90% W=11.07 kW
Centrifugation (P-6) W= 29.9 kW
Fermentor (P-9 /Ferment) Agitation Rme =90%
Cooling
W=1.2 kW
Q =11.96 kW (-)
Pumps: (P-10/PM-1) Rme=70%
(P-10/PM-2) Rme=70%
(P-10/PM-3) Rme=70%
W=0.03 kW
W=0.03 kW
W= 2.80 W
Evaporator (P-11/HXF) Rth =90% Q=63.63 Kw
Condensation (P-12/HX-2)
Rth =90%
Q=3.38 kW (-)
Distillation (dist-1)
Condenser
Boiler
Qc=1058.22 kW (-)
Qb=1094.59 kW
Distillation (dist-2)
Condenser
Boiler
Qc=119.9 kW (-)
Qb=120.78 kW
Distillation (dist-3)
Condenser
Boiler
Qc=226.07 kW (-)
Qb=249.3 kW